SP1902 004 (Web Near End) can be adjusted to change the near-end period. The
defaults for and amount of web that remains for copying are different for NA and
EUR/A.
Near-End
Area
Near-End
NA
90%
EUR/A
86%
The table below, provided for your reference, shows approximately how adjustment of
SP1902 002 affects the near-end and end displays on the B070 (90 cpm) or B071
(105 cpm).
Note that adjustment of SP1902 002 also affects SP1902 005 (Web Motor Control –
Web Motor Drive Interval (Low Speed)).
SP1902 002
B070
B071
20.7 s
17.0 s
15.6 s
12.8 s
12.1 s
10.0 s
10.4 s
8.5 s
6.9 s
5.7 s
12.6 s
10.4 s
10.8 s
9.0 s
7.2 s
6.0 s
*1
: SP1902 002 (Web Motor Control – Web Motor Drive Interval)
*2
: SP1902 005 (Web Motor Control – Web Motor Drive Interval (Low Speed))
*3
: SP1902 004 (Web Motor Control – Web Near End Setting)
*4
: Calculated based on A4 LEF at 100% magnification.
NOTE: SP1902 003 (Web Motor Control – Web Near End Setting) not adjusted.
PTM
Web Remaining
600K
350K
*1
Low
SP1902 004
Speed
*2
Mode
25.3 s
90%
19.0 s
90%
14.8 s
90%
12.7 s
90%
8.5 s
90%
15.4 s
86%
13.2 s
86%
8.8 s
86%
2-76
Near-End
End Display
*3
Display
(Sheets)
*4
(Sheets)
600K
450K
350K
300K
200K
350K
300K
200K
Comments
670K
NA Default
500K
385K
330K
220K
410K
EUR/A Default
350K
230K
B070/B071