EN
WEATHER STATION Solight TE81
User's Manual
User's Manual Dear customer, thank you for purchasing our product. If you want to safely make full use of the features, please carefully read these instructions
and follow them. This way, you will avoid incorrect use or damage. Prevent unauthorized use of this device and always respect all rules regarding the handling of
electrical devices. Please, keep the manual for future use. The main unit should be as close to a window as possible.
TECHNICAL SPECIFICATIONS
Room Temperature Measurement
Room Humidity Measurement
Outside Temperature Measurement
Outside Humidity Measurement
Power supply
Temperature Measurement Accuracy
Humidity Measurement Accuracy
Atmospheric Pressure Measurement Range
Main Unit
If the unit is to be powered by batteries open the battery compartment cover and insert two alkaline AA batteries (not included). Mind the indicated polarity.
When powering up, for a moment, all of the LCD segments light up and the device makes a beep sound. It then goes into the standard temperature and
humidity measurement mode.
When the device is powered by an AC/DC adapter connect the power connector to the input socket on the weather station and then connect the adapter to a
power socket.
To reset the device, remove and reinsert the batteries or disconnect the adapter for at least five seconds. This will delete all settings and memory. When
powered by batteries, the display stays lit for eight seconds after each activation. When powered by the adapter, it stays lit continuously.
The main unit can be paired with up to three sensors. Each sensor is powered by two alkaline AA batteries (not included).
Default Settings:
24-hour time format showing 00:00, pressure in mb/hPa and temperature in °C.
1.
BUTTON FUNCTIONS
Controls
Functions
Display
Brief
date / sec
push
Standard
mode
Access
time
HOLD
setting
mode
Brief
Confirm
push
setting
Setting
Time
HOLD
-----
Brief
-----
push
Setting the
Alarm Clock
HOLD
-----
Brief
-----
Setting the
push
temperatur
e alarm
HOLD
-----
2.
MAIN FUNCTIONS
6 graphic levels of weather forecast: sunny, scattered clouds, cloudy, rainy, heavy rain, snow
RCC Signal Reception Mode: DCF
Calendar Span: 2000-2099, displaying date and day of the week
Time format 12/24 hours
0°C to +50°
20% to 95%
-20°C to +60°C
20% to 95%
2x AA 1.5V alkaline battery
AC/DC adapter 5V/1200mA
1°C
5%
600 hPa/mb – 1,100h Pa/mb
Toggle between
Display
°C/°F
alarm time
/ date
Access
alarm
RCC reception
clock
mode activation
setting
mode
-----
One step forward
-----
Fast forward
-----
One step forward
-----
Fast forward
-----
One step forward
-----
Fast forward
We recommend using alkaline batteries with a nominal voltage of 1.5 V to
achieve the correct luminosity of the LCD display. NiMh accumulators
usually have a voltage of 1.2 V causing the LCD luminosity to be inferior.
Toggle individual
Turns the
sensors / cyclical
temperatu
sensor display
re alarm
mode
on/off
Access
Sensor signal
temperatu
reception
re alarm
activation
setting
mode
One step back
-----
Fast backward
-----
One step back
-----
Fast backward
-----
Toggling
the max.
One step back
and min.
temperatu
re settings
Fast backward
-----
MEM
Display
stored max.
Change the
and min.
backlight
temperature
intensity
s and
humidity
Delete data
Enter pressure:
about max.
unit change
and min.
mode/forecast
temperature
change mode
s and
humidity
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
on/off
Z
/ Z
Turn on
Turn
display
alarm
backlight /
on/off
snooze
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
Need help?
Do you have a question about the TE81 and is the answer not in the manual?
Questions and answers