5.2.8.

Port Monitoring Config

Select "Advanced Config" and then "Port Monitoring Config" to open the screen
shown in Figure 5-22. On this screen, you can configure the port monitoring set-
tings.
Screen Description
Monitor Output Port
Monitor Target Port
Monitor Direction
Monitor Status
Note:
Mirror packets in transmission direction will include the VLAN tag of the
received VLAN ID.
Figure 5-22 Port Monitoring Configuration
Indicates a port number of a port used to monitor packets for another port.
Indicates a port number of a port being monitored.
The factory default setting is 2.
Displays which of transmit packets or receive packets are monitored at the
port to be monitored.
"Send/Recv" is the factory default setting.
Recv
Monitors receive packets.
Send
Monitors transmit packets.
Send/Recv Monitors both transmit and receive packets.
Indicates whether monitoring is enabled.
"Disable" is the factory default setting.
Enable
Monitors packets.
Disable
Does not monitor packets.