Technical Data; Reference Conditions; Limitations; Compressor Data - Atlas Copco LF 2 Instruction Book

Industrial aluminium piston compressor
Hide thumbs Also See for LF 2:
Table of Contents

Advertisement

Instruction book
8

Technical data

8.1

Reference conditions

Inlet pressure (absolute)
Relative air humidity
Air inlet temperature
Working pressure:
for LF 10 bar
8.2

Limitations

Minimum inlet temperature
Maximum inlet temperature
Maximum working pressure
Only applicable for Full Feature variants. (with refrigerant dryer)
Minimum ambient air temperature
8.3

Compressor data

50 Hz (10 bar)
Compressor
type
Maximum
working
pressure
Maximum
working
pressure for
Trolley
Pre-set
pressure
difference for
Trolley
Temperature at outlet valve, approx.
- Unsilenced
compressor
- Silenced
compressor
Power input at
maximum
working
pressure
2920 7090 00
bar
%
ºC
bar(e)
°C
ºC
bar(e)
°C
LF 2
bar(e)
10
bar(e)
9.5
bar
1
ºC
40
ºC
48
kw
2.05
LF 3
LF 5
10
10
9.5
9.5
1
1
44
45
52
53
2.71
5.11
1
0
20
7
0
40
See below
5
LF 7
LF 10
10
10
9.5
9.5
1
1
50
51
58
59
5.89
8.65
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf 5Lf 3Lf 7Lf 10

Table of Contents