Atlas Copco LF 2 Instruction Book page 56

Industrial aluminium piston compressor
Hide thumbs Also See for LF 2:
Table of Contents

Advertisement

Ref
1
2
3
4
5
Function
The adjustment of the maximum or stopping pressure of the compressor is effected by means of the air
pressure switch. The switch also controls the pressure difference between the maximum pressure (stopping
pressure) and the pressure at which compression is resumed (starting pressure).
Adjustment
The maximum pressure is controlled by adjusting screw (4). Turn the screw clockwise to raise the
maximum or stopping pressure, counter-clockwise to lower it.
The pressure difference is adjusted by means of screw (5). To reduce the difference between the stopping
and starting pressures, i.e. to increase the starting pressure, turn the screw counter-clockwise. To increase the
pressure difference, turn the screw clockwise. The adjustment range is shown on the pressure difference
diagram below.
Diagramme différence de pression MDR4-11bar
Ref
1
2
54
Name
Air pressure switch
Solenoid valve
Pressure release valve
Adjusting screw, stopping pressure
Adjusting screw, pressure difference
Adjust the air pressure switch while it is pressurized.
Switch off the voltage before removing the cover of the switch; reinstall it after an
adjustment has been made and before the voltage is switched on again.
Name
Starting pressure - bar(e)
Stopping pressure - bar(e)
Instruction book
2920 7090 00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf 5Lf 3Lf 7Lf 10

Table of Contents