Period
Operation
Inspect and clean the filter of the steam trap.
Daily
Brush or blow off the finned surface of the condensor.
Weekly
Note (Full Feature units):
Regularly check that the condensate is discharged via the condensate outlet of the refrigerant dryer. The
amount depends on the operation conditions.
5.3

Service kits

Service kits are available, offering the benefits of genuine Atlas Copco parts while keeping the maintenance
budget low. The kits comprise all parts needed for servicing. Consult the Parts list for the contents of all kits.
Reference
Operation
1
Valve kit
2
Filter kit
3
Check valve
4
Unloader
Notes:
1. Use only authorized parts. Any damage or malfunction caused by the use of
2. Whichever interval comes first. The local Sales Company may overrule the
3. For the contents of all kits, consult the Parts list.
5.4

Disposal of used material

Used filters or any other used material (e.g. desiccant, lubricants, cleaning rags, machine parts, etc.) must be
disposed of in an environmentally friendly and safe manner, and in line with the local recommendations and
environmental legislation.
50
unauthorized parts is not covered by Warranty or Product Liability.
maintenance schedule, especially the service intervals, depending upon the
environmental and working conditions of the compressor.