Instruction book
Ref
A
R
1
2
3
4
Unload mechanism
The pilot valve is equipped with a hand-operated unload mechanism: by turning the red handle (1) 90
degrees, the plunger of the valve will be lifted, releasing the spring force. The air pressure from
pulsation dampers will force down unloader plunger (8) and the compressor will run unloaded.
turning handle (1) 90 degrees further, the plunger returns to its original position so that the pilot
will again unload and load the compressor at the pre-set pressures.
Setting of the pilot valve
The maximum pressure is controlled by adjusting screw (2):
1.
Loosen handle (1) and the two nuts (3)
2.
Turn the adjusting screw (2) clockwise to increase the maximum pressure.
3.
The pressure difference can be increased by removing one or more shims (4).
4.
Fit the two nuts (3) and handle (1) in their original position.
6.7

Safety valve

If safety valve is not used for longer than 6 months, pressurize for 4h to have working pressure
Testing
1. Close the air outlet valve, depressurize and disconnect the hose or pipe from the valve
2. Start the compressor and run it until it stops automatically.
3. Switch off the voltage.
Remove the cover from the air pressure switch and, with the air receiver now under pressure, turn the
adjusting screw one turn clockwise to increase the stopping pressure Adjustment of MDR4S pressure switch
and Adjustment of MRD3 pressure switch. Reinstall the cover.
4. Switch on the voltage, slightly open the outlet valve and start the compressor
5. Gradually close the outlet valve while checking the air pressure gauge. If the safety valve has not opened at
the pressure specified in Compressor data, it must be replaced by a new one. If the compressor unloads
before the specified opening pressure is reached, repeat the procedure as mentioned from step 3.
6. Readjust the unloading pressure as described in sections Adjustment of MDR4S pressure switch and
Adjustment of MRD3 pressure switch
7. Reconnect the hose or pipe to the closed air outlet valve
2920 7090 00
Description
Control air to unloader
Vent hole
Unloading handle
Pressure adjusting screw
Nuts
Shims
Replace the valve if it does not open at the correct pressure. No adjustment is
allowed. Testing: Testing as described below shall only be carried out by competent
personnel.
If safety valve is not used for longer than 6 months, pressurize for 4h to have working
pressure