Pressure difference diagram, MDR3/11 (10 bar units)
Example:
Stopping pressure: 7 bar(e)
Starting pressure: adjustable between 3 and 5.7 bar(e)
Ref
1
2
6.6

Adjustment of pilot valve on Trolley

The adjustment of the maximum or unloading pressure of the compressor is effected by means of pilot valve
(RV) The valve also controls the difference between the preset maximum pressure and that at which
compression is resumed.
Pilot valve on Trolley
56
Name
Starting pressure - bar(e)
Stopping pressure - bar(e)