7. How to calibrate the air probe
If the actual cellar temperature differs from the setting temperature, set
parameter ot = actual cellar temperature minus set-point.
8. How to adjust defrost settings
In case there is excessive frost, the parameters FnC = C-y, idF = 4 and MdF =
20 can be used to avoid frost.
9. How to adjust the humidity
The parameter Fon is used to adjust the humidity in the wine cellar. Higher Fon
results in higher relative humidity.
humidity.
10. How to set alarm call
1)
Speech notice will be sent to your phones when the cellar temperature is ALU
higher or ALL lower than the set-point Set.
2) In order to test the call function, set parameters Ald = 0 and dAO = 0. After
testing, set Ald = 60 and dAO = 23.
11. How to set cellar heater
The heater turns on at SAA minus Shy; the heater turns off at SAA.
Use a forced air heater to warm up the wine cellar.
If there is a thermostat on the heater, bypass it or set the
NOTE
thermostat at the highest level.
If the heater runs more than 10 A current, use a 120VAC coil
contactor.
Use a separate hygrometer to monitor the
- 9 -