Long Time Measurement; Power Display In The Status Line Of The "Machine" Operating Area - Siemens SINUMERIK 840D sl Ctrl-Energy System Manual

Hide thumbs Also See for SINUMERIK 840D sl Ctrl-Energy:
Table of Contents

Advertisement

Ctrl-E Analysis

3.6 Power display in the status line of the "Machine" operating area

3.5

Long time measurement

In order that you can read the usage values in the Ctrl-Energy initial window and in the "Long
time measurement" window, program the PLC user program as specified in Chapter 2.3.1.1
(840D sl) or 2.3.2.1 (828D).
3.6
Power display in the status line of the "Machine" operating area
The current energy consumption is displayed in the first line of the status display in the
"Machine" operating area in the form of colored bars.
To show the power display set DB1001.DBX3.0 = 1 in the STEP 7 program of the PLC.
The following machine statuses are displayed:
DB1001.DBB96 = 0
DB1001.DBB96 = 1
DB1001.DBB96 = 2
38
Displaying the machine status
Red bar upwards – the machine is unproductive
Dark green bar upwards – the machine is productive and consumes
energy
Light green bar downwards – the machine feeds energy back into
the line supply (generator operation)
System Manual, 01/2015, 6FC5397-0EP40-5BA2