7
Connection
7.2.4
Cooling Water Outlet
The cooling water leaving the system can be directed to the sewer system, reused and recooled
because it circulates through the machine in a closed system and does not come into contact
with the solvent. You should endeavor to reuse the cooling water.
7.2.5
Compressed Air
The operating pressure is 6 bar (87 psi). The machine is equipped with a compressed air
reducing valve, pressure gauge and compressed air water separator. The line pressure should
be 10 - 12 bar (145 - 174 psi).
7.2.6
Process Water
Empty the process water collecting tank daily.
Dispose of the contents according to the regulations for your country.
7.2.7
Aeration Lines
The venting ducts of the machine must lead without diminished cross section into the open or via
open funnel and cock valve to the room venting system (if existing).
It must be ensured that the venting does not lead to areas with high
explosion risks or to ignitation sources.
43
43
7
M12-M15-M18