Cooling Water Outlet; Compressed Air; Process Water; Aeration Lines - BÖWE M12 Installation Instructions Manual

Hide thumbs Also See for M12:
Table of Contents

Advertisement

7
Connection
7.2.4

Cooling Water Outlet

The cooling water leaving the system can be directed to the sewer system, reused and recooled
because it circulates through the machine in a closed system and does not come into contact
with the solvent. You should endeavor to reuse the cooling water.
7.2.5

Compressed Air

The operating pressure is 6 bar (87 psi). The machine is equipped with a compressed air
reducing valve, pressure gauge and compressed air water separator. The line pressure should
be 10 - 12 bar (145 - 174 psi).
7.2.6

Process Water

Empty the process water collecting tank daily.
Dispose of the contents according to the regulations for your country.
7.2.7

Aeration Lines

The venting ducts of the machine must lead without diminished cross section into the open or via
open funnel and cock valve to the room venting system (if existing).
It must be ensured that the venting does not lead to areas with high
explosion risks or to ignitation sources.
43
43
7
M12-M15-M18

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for BÖWE M12

This manual is also suitable for:

M15M18

Table of Contents