Extension Cord Length
Wire Size................. 18 A.W.G.
Up to 50 ft
NOTE: Using extension cords over 50 ft. long is not
recommended.
MOTOR
The dust collector is assembled with motor and wiring
installed. The electrical wiring schematic is shown in
Figure 5.
4
The permanently split capacitor motor has the following
specifications:
Horsepower (Peak HP) ............................................ 1-1/2
Voltage ...................................................................... 120
Amp ............................................................................ 9.5
Hertz ............................................................................ 60
Phase .................................................................... Single
RPM ......................................................................... 3100

ELECTRICAL CONNECTIONS

WARNING
All electrical connections must be performed by a qualified
electrician. Make sure tool is off and disconnected
from power source while motor is mounted, connected,
reconnected or anytime wiring is inspected. Motor and
wires are installed as shown in wiring schematic (See
Figure 5). Motor is assembled with approved, 3-conductor
cord to be used at 120 volts.
Figure 5
The power lines are inserted directly into the switch. The
green ground line must remain securely fastened to the
frame to properly protect against electrical shock. The
power supply to the motor is controlled by a single pole
locking rocker switch.