GROUNDING INSTRUCTIONS

WARNING
Improper connection of equipment grounding conductor can
result in the risk of electrical shock. Equipment should be
grounded while in use to protect operator from electrical shock.
grounding instructions or if you are in doubt as to whether the
tool is properly grounded.
• This tool is equipped with an approved cord rated at 120V
and a 3-prong grounding type plug (see Figure 4) for your
protection against shock hazards.
• Grounding plug should be plugged directly into a properly
installed and grounded 3-prong grounding type receptacle, as
shown (see Figure 4).
Figure 4
Properly Grounded Outlet
3-Prong Plug
Do not remove or alter grounding prong in any manner. In the
event of a malfunction or breakdown, grounding provides a
path of least resistance for electrical shock.
WARNING
installing or removing from outlet.
• Plug must be plugged into matching outlet that is properly
installed and grounded in accordance with all local codes and
• Inspect tool cords periodically, and if damaged, have repaired
• Green (or green and yellow) conductor in cord is the
grounding wire. If repair or replacement of the electric cord
or plug is necessary, do not connect the green (or green and

EXTENSION CORDS

• The use of an extension cord is not recommended. The use of any
extension cord will cause some drop in voltage and loss of power.
the current and maintain adequate voltage.
• Use the table to determine the minimum wire size (A.W.G.)
extension cord.
• Use only 3-wire extension cords having 3-prong grounding
type plugs and 3-pole receptacles which accept the tool plug.
• If the extension cord is worn, cut or damaged in any way,
Replace it immediately.
Extension Cord Length
Wire Size ........... A.W.G
Up to 50 ft .........14 gauge
NOTE: Extension cord over 50 ft. NOT RECOMMENDED.
Grounding Pin

MOTOR

The dust collector is assembled with motor and wiring installed.
The permanently split capacitor motor has the following
Horsepower (Peak HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120/240
Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12/6
Hertz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single
RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3450

ELECTRICAL CONNECTIONS

WARNING
electrician. Make sure tool is off and disconnected from power
source while motor is mounted, connected, reconnected or
anytime wiring is inspected. Motor and wires are installed as
shown in wiring schematic (See Figure 5.) Motor is assembled
Figure 5
The power lines are inserted directly into the switch. The green
ground line must remain securely fastened to the frame to
properly protect against electrical shock. The power supply to
TO CONVERT TO 240V POWER SUPPLY
To convert the dust collector to 240V the switch box must be
inspect the switch box and new plug before the dust collector is
meet these requirements:
Circuit Type . . . . . . . . . . . . . . . . . . . . 240V, 60 Hz, Single Phase
Current Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Amps
Plug Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 6-15