Download Print this page

Electrical Specifications - Sealey TA304 Instructions Manual

Digital automotive analyser 15 function with ic/i

Advertisement

Note: Infrared measurement considerations.
Holding the laser unit in your hand, direct the laser/Ir sensor toward the
object whose temperature is to be measured bearing in mind the field of
view requirements shown in fig.12. the meter automatically
compensates for temperature deviations due to the ambient
temperature. If a higher temperature is to be measured after taking a
low temperature measurement, it is advisable to wait several minutes
between the measurements for the infrared sensor to cool. Keep in mind
that it may take up to 30 minutes to adjust to wide ambient temperature
differences.
INFRARED TEMPERATURE PROBE SPECIFICATION
response rate
0.5 seconds approx.
operating temperature
32ºf to 122ºf (0ºc to 50ºc)
operating Humidity
Max 80% rH.
Power supply
9V battery (PP3)
Weight
182g
size
164 x 50 x 40mm
Ir thermometer range
-30 to 550ºc (-22ºf to 1022ºf)
Ir thermometer output
1mV = 1ºc or 1ºf
Ir thermometer
± 2% of reading or 4ºf whichever is greater. note:
accuracy
accuracy is specified for the following ambient
temperature range: 64 to 82ºf (18 to 28ºc)
Emissivity
0.95 fixed value
field of view
D/s Approx. 8.1 (D = distance & s = spot) Has
90% encircled energy at focal point.
Laser Power
Less than 1mW
spectral response
6 to 14 µm (wavelength)
GENERAL INSTRUMENT SPECIFICATION
Instrument complies with
Insulation
overvoltage category
Display
Polarity
overrange
Low battery indication
Measurement rate
Auto power off
operating environment
storage temperature
for inside use, max height
Pollution degree
Power
Dimensions
Weight

6. ELECTRICAL SPECIFICATIONS

DWELL ANGLE
Cylinder
Range
4cYL
0 ~ 90.0º
5cYL
0 ~ 72.0º
6cYL
0 ~ 60.0º
8cYL
0 ~ 45.0º
© Jack sealey Limited
IEc 1010-1 En61010-1
class 2, Double Insulation
cAtIII1000V/cAtIV600V
4000 counts LcD display with
function indication
Automatic, (-) negative polarity indication.
"oL" marks indication
"BAt" is displayed when the battery
voltage drops below the operating level
2 times per second, nominal
Meter automatically shuts down after
approx. 30 seconds of inactivity
0ºc to 50ºc (32ºf to 122ºf) at < 70%
relative humidity.
-20ºc to 60ºc (-4ºf to 140ºf) at < 80%
relative humidity.
2000m
2
one 9V battery (PP3)
182 x 82 x 55mm
360g
Resolution
Accuracy
0.1º
±2% of rdg ± 4dgts
Original Language Version
Electrical Specification (ACCURACY).
Accuracy is given as ± ([% of reading] + [number of least significant
digits]) at 18ºc to 28ºc (65ºf to 83ºf), with relative humudity up to 70%.
RPM (tach)
Range
rPM4
600 ~ 4000 rPM
1000 ~ 12000
rPM. (x10 rPM)
rPM 2/DIs
300 ~ 4000 rPM
1000 ~ 6000
rPM. (x10 rPM)
Effect reading: >600rPM
DC VOLTAGE
Range
400.0mV
4.000V
40.00V
400.0V
600V
Input Impedance: 10MΩ
AC VOLTAGE
Range
400.0mV
4.000V
40.00V
400.0V
600V
Input Impedance: 10MΩ / Frequency Range 50 to 60Hz
DC CURRENT
Range
40.00mA
400.0mA
20A
overload Protection: 0.5A / 250V and 20A / 250V fuse
Maximum Input: 400mA Dc or 400mA Ac rMs on uA / mA ranges,
20A Dc or Ac rMs on 20A range.
AC CURRENT
Range
40.00mA
400.0mA
20A
overload Protection: 0.5A / 250V and 20A / 250V fuse
frequency range: 50 to 60Hz
Maximum Input: 400mA Dc or 400mA Ac rMs on uA / mA ranges,
20A Dc or Ac rMs on 20A range.
RESISTANCE
Range
400.0Ω
4.000kΩ
40.00kΩ
400.0kΩ
4.000MΩ
40.00MΩ
Resolution
Accuracy
1 rPM
10rPM
±2% of rdg ± 4dgts
1 rPM
10rPM
Resolution
Accuracy
0.1mV
±0.5% of rdg ± 3dgts
1mV
±1.5% of rdg ± 2dgts
10mV
100mV
1V
±1.8% of rdg ± 2dgts
Resolution
Accuracy
0.1mV
±1.5% of rdg ± 5dgts
1mV
±1.0% of rdg ± 3dgts
10mV
±1.5% of rdg ± 3dgts
100mV
1V
±2.0% of rdg ± 4dgts
Resolution
Accuracy
10uA
±1.5% of rdg ± 3dgts
100uA
10mA
±2.5% of rdg ± 5dgts
Resolution
Accuracy
10uA
±1.8% of rdg ± 5dgts
100uA
10mA
±3.0% of rdg ± 7dgts
Resolution
Accuracy
0.1Ω
±1.2% of rdg ± 4dgts
±1.0% of rdg ± 2dgts
10Ω
100Ω
±1.2% of rdg ± 2dgts
1kΩ
10kΩ
±2.0% of rdg ± 3dgts
tA304 Issue:4(I) - 17/06/14

Advertisement

loading