Technical Data - Baxi Power HT Series Installation, Operation And Maintenance Manual

Floor standing condensing gas boilers
Table of Contents

Advertisement

Available languages

Available languages

Boiler model POWER HT
Category
Maximum heat input
Minimum heat input
Maximum heat output 75/60°C
Maximum heat output 50/30°C
Minimum heat output 75/60°C
Minimum heat output 50/30°C
Useful efficiency according to 92/42/CEE directive
Central heating system max. pressure
Heating circuit temperature range
Type
Flue duct diameter
Max. flue mass flow rate
Min. flue mass flow rate.
Max. flue temperature
NOx class
Type of gas used
Natural gas feeding pressure 2H
Propane gas feeding pressure 3P
Power supply voltage
Power supply frequency
Rated power supply
Net weight
Dimensions
*C53 (only with air intake kit)
BAXI S.p.A., in its commitment to constantly improve its products, reserves the right to alter the specifications contained herein at any time
and without previous warning. These Instructions are only meant to provide consumers with use information and under no circumstance
should they be construed as a contract with a third party.
ISTRUCTIONS PERTAINING TO THE INSTALLER

22. TECHNICAL DATA

kW
kW
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
bar
°C
mm
kg/s
kg/s
°C
mbar
mbar
V
Hz
W
kg
height
mm
width
mm
depth
mm
109
1.850
1.1000
1.1200
II
II
II
2H3P
2H3P
2H3P
87,2
102,7
123,2
33,1
36,8
40
85
100
120
73100
86000
103200
91,6
107,8
129,7
78776
92708
111542
32,2
35,8
39
27692
30788
33540
34,9
38,8
42,1
30014
33368
36206
★★★★
★★★★
★★★★
4
4
4
25÷80
25÷80
25÷80
B23 - B23P - C53*
100
100
100
0,041
0,049
0,059
0,016
0,018
0,019
78
80
77
5
5
5
G20
G20
G20
G31
G31
G31
20
20
20
37
37
37
230
230
230
50
50
50
100
160
135
75
83
95
850
850
850
450
450
450
801
871
1024
1.1500
II
2H3P
154
41,5
150
129000
162
139320
40,4
34744
43,7
37582
★★★★
4
25÷80
100
0,073
0,020
75
5
G20
G31
20
37
230
50
235
103
850
450
1132
910.001.1 - EN