Diagnostics and troubleshooting

8
Diagnostics and troubleshooting
8.1

General causes of errors

Error
Status LED PWR off
Status LED ACT red
continuous light
and
status LED READ green
continuous light
for more than approx. 3s
Status LED ACT red
continuous light
After activation and
with transponder in read
field:
Status LED READ not
flashing green
8.2

Interface error

Error
No communication via
RS232 / RS 422 / RS485
Sporadic error on
the RS232 interface
54
Possible cause of error
• No supply voltage connected to
the device.
• Hardware error.
• Error during initialization.
• Device deactivated or device acti-
vated, but no transponder
detected.
• Device activated, but no transpon-
der detected.
Possible cause of error
• Wiring not correct.
• Influences from electromagnetic
interference (EMC).
RFM - HF RFID Series
Remedial measures
• Check supply voltage.
• Send device to customer service.
• Switch the supply voltage off
and on again.
• Send device to customer service.
• Check wiring of trigger.
• Check enable of the transponder type in
the configuration.
Remedial measures
• Check wiring.
• Check shield
(shield overlap up to the clamping point!).
• Avoid electromagnetic interference from
high-voltage power lines running parallel.