Commissioning and configuration
7.6
LED indicators
LED
State
PWR
READ
ACT
PWR
ACT
READ
Table 7.4:
52
Meaning
Device OFF
Off
Green
continuous light
Device OK, initialization phase
and
red
continuous light
for approx. 3s
Yellow,
Device ready
continuous light
Device (antenna) activated
Red,
continuous light
Transponder has been detected
Green, flashing
LED indicators and their meaning
RFM - HF RFID Series
- No supply voltage
- Self test running
- Reading gate open/precharged for writing
- Transponder is expected
- Data output via interface
Leuze electronic