General Specifications Of The Rfm 32 Sl 200 Read/Write Systems (Ex N) - Leuze electronic RFM 32 SL 200 Technical Description

Statinary rfid read/write systems, transponders
Table of Contents

Advertisement

Specifications
4.2

General specifications of the RFM 32 SL 200 read/write systems (Ex n)

General specifications
Working frequency
Reading range
Writing range
Data carrier speed
Memory access
Data protocols
Electrical data
Operating voltage VCC
Power consumption
Host interface
Data frame
Indicators
LED green
LED yellow
LED red
Mechanical data
Housing
Weight
Dimensions
Environmental data
Ambient temp.
(operation/storage)
Relative air humidity
Standards and directives
Protection class
Explosion protection
Certification (CENELEC)
1) Depends on transponder, reading type and reading distance used, and the temperature. Above
an ambient temperature of 50°C, the operating range decreases by up to 20%.
22
1)
1)
1)
Baud rate 9600
Protocol 8 data bits, 1 stop bit, 1 start bit, no parity
Prefix 1 02h = STX
Postfix 1 0Dh = CR
Postfix 2 0Ah = LF
RFM - HF RFID Series
RFM 32 SL 200
13.56MHz
max. 110mm, 85mm recommended (transponder
Ø 50mm)
max. 95mm, 70mm recommended (transponder
Ø 50mm)
max. 6.0m/s
write/read - approx. 50ms/block typical
ISO 15693, e.g., NXP I-Code (1+2), Texas Instruments
Tag-It / Tag-It HFI, Infineon my-d vicinity
12 ... 30VDC
max. 1.2W, typ. 45mA at 24VDC
RS 232
STX DATA CRLF
read process (not online!)
voltage supply
activation (trigger)
ABS, black
approx. 280g
101.5 x 75.5 x 30mm
-25°C ... +65°C/
-40°C ... +70°C
5 ... 90% (non-condensing)
R&TTE 1999/5/EC,
EN 60950-1,
EN 300330-2,
EN 301489-1/3
IP 67 acc. to EN 60529
RFM 32 SL 200 Ex n
max. 5.0m/s
ABS, black, molded
approx. 500g
-25°C ... +60°C/
-40°C ... +70°C
R&TTE 1999/5/EC,
94/9/EC
EN 50021
EN 60950-1,
EN 300330-2,
EN 301489-1/3
II 3G Ex nA IIB T4
II 3D Ex tD A22 IP67 T80°C
Leuze electronic

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rfm 32 sl 200 ex nRfm seriesRfm 12 sl 200

Table of Contents