Assembly

Requirements

Requirement for safe assembly: You have
read chapter „For your safety" on page GB-4
and understand all the safety notices.

Connection for power supply

WARNING
Risk of electric shock!
The mains plug must be as accessible
as possible during use, i.e. the plug
must be accessible even after the ex-
haust hood has been installed.
If the mains plug is no longer acces-
sible after installation, an all-pole dis-
connecting device complying with
overvoltage category III must be con-
nected to the house wiring with a con-
tact gap of at least 3 mm; this includes
fuses, circuit breakers and contactors.
Electrical installation may be per-
formed only by a certifi ed specialist.
If an additional socket is required,
have an electrician perform the in-
stallation.
Do not connect to a multiple socket
outlet, power strip, timer or to a sepa-
rate remote-controlled system for dis-
tance monitoring and control.
To ensure that the exhaust hood will perform
optimally and that no obtrusive cabling is visi-
ble afterwards, plan the connection for power
supply carefully before installation: The ex-
haust hood must be placed over the centre
of the cooking zone.
Assembly

Substructure or wall mounting

Substructure
WARNING
Risk of electric shock!
Failure to install mounting screws or
fasteners contrary to this instruction
may cause electrical hazards.
CAUTION
Fire hazard!
The distance between the cooking
surfaces and the lower edge of the
hood must be at least 70 cm for gas
and electric stoves, 80 cm for coal
and oil-fi red stoves.
For gas stovetops, you must read the
user manual for the stovetop! If the
manual stipulates a larger distance,
this must be observed.
The ventilation grilles must remain
clear.
You can screw the exhaust hood under a wall
unit. The wall unit must have the following di-
mensions:
Minimum width: 60 cm
Minimum depth: 33 cm
For the substructure, you must observe the
above mentioned minimum distances to
the hob (70 cm for gas and electric stoves,
at least 80 cm for coal and oil-fired stoves).
When measuring the distance, take into ac-
count the height of the exhaust hood of 8 cm.
For the substructure, you will need:
– the supplied mounting parts (2) to (4)
– drill with stone bit, correctly sized for the
supplied screws (2).
– Screwdriver
– Pencil
– Stable stepladder
– A second person to help
– Work gloves
Page GB-7