2) The unit comes preset at 50W as shown in Figure 4. Unscrew the terminal with the red
wire. It is marked 50W. Remove the wire from the 50W terminal and insert it into the
desired terminal, 100W or 200W. Tighten the terminal. Note: Confirm that all of the non-
used screws in the terminal block are tight. Refer to section 4.0 (Wiring) for more detailed
wiring diagrams.
3) Reinstall the cover plate on the electronics compartment and tighten the 4 Torx head
screws (T-20).
4.0 WIRING
The TCPA-Omni has an integrated circuit breaker that protects itself from line surges and short
circuits. The circuit breaker is located under the cover plate next to the power tap section terminal
block. If the breaker would trip follow the steps below:
1) Remove the side cover plate
2) Push to Reset the breaker (the button on the breaker should push in and stay)
3) Install the side cover
The diagrams on the next page show typical wiring installation for the 50, 100, and 200 watt
configurations.
Note: When placing multiple wires under a terminal on the terminal block put one wire on each
side of the screw.
90185A-MAN-OMNI
Figure 4: Wiring for 50W system
Copyright © Ultra Electronics – USSI , Columbia City, IN 46725 USA
®