4.4 Cooling water inlet temperature (plug-on shaft)

Constituent
Sulfate ions
Nitrate ions
Dissolved solids
Max. grain size
Operating pressure
Inlet temperature
Minimum cooling water inlet temperature
Anti-freeze protection / corrosion protection
NALCO 00GE056 inhibitor
4.4
Cooling water inlet temperature (plug-on shaft)
Cooling water intake temperature
The maximum cooling water intake temperature is 25 °C.
NOTICE
Condensation for an excessively low cooling water intake temperature
If the temperature difference between cooling water and ambient temperature is greater than
5 K, this may result in condensation forming in the machine. This results in material damage.
● Make sure that the condensation can drain away freely.
● Adopt appropriate measures to achieve the required intake temperature of the cooling
● Alternatively, dry the ambient air.
4.5

Noise emissions

Noise emissions
During operation, the machine's noise emission levels can exceed those permitted at the
workplace, which can cause hearing damage.
● Ensure that nobody is in the area of increased noise emissions during machine operation.
● Take steps to reduce noise so that the machine can be operated safely within your system.
26
water.
The following measures may help to reduce noise.
– Covers
– Noise insulation
– Hearing protection measures
Value
< 50 ppm
< 50 ppm
< 340 ppm
< 100 μm
6 bar max.
< 25 °C
T
> T
- 5 K
cooling water
ambient
20 ... 30 %
0.2 ... 0.25 %