Removing the Scalability Terminator

Removing the Scalability Terminator
Upgrading to the UCS B460 M4 blade server requires that you remove the UCS Scalability Terminator from
a UCS B260 M4 blade server. If you do not plan to upgrade to a UCS B460 M4 Blade Server, you should not
need to remove the UCS Scalability Terminator from a UCS B260 M4 Blade Server.
Before you begin
Decommission the blade server using Cisco UCS Manager to take the server offline.
Procedure
Step 1
Completely loosen the captive screws on the front of the UCS Scalability Terminator. See callout 1 in the
following figure.
Step 2
Open both ejector levers on the front of the UCS Scalability Terminator. See callout 2 in the following figure.
Step 3
While holding the ejector levers open, pull the UCS Scalability Terminator away from the blade server to
separate it from the blade server. See callout 3 in the following figure.
Step 4
Once removed, place the UCS Scalability Terminator on an antistatic mat or antistatic foam.
Figure 22: Removing the Scalability Terminator

Installing a Scalability Connector

Use a UCS Scalability Connector to connect together two UCS Scalable M4 Blade Modules and form the
UCS B460 M4 Blade Server.