Millivolt Appliance Checkout; Electronic Appliance Checkout; Log Placement - Superior B-40REN Homeowner's Care And Operation Instructions Manual

Standard series 36" b-vented gas appliances
Hide thumbs Also See for B-40REN:
Table of Contents

Advertisement

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
The top " (9 mm) at the pilot generator (ther-
mopile) should be engulfed in the pilot flame.
The flame should project 1" (25 mm) beyond
the hood at all three ports (Figure 8 ) .

Electronic Appliance Checkout

Light the burner, refer to the Lightilng Instruc-
tions in this manual. Ensure the ignitor lights
the pilot. The pilot flame should engulf the
flame rod as shown in Figure 8.
With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If you
should experience any problem, first refer to the
trouble shooting guide in this manual. If problem
persists, contact your Superior distributor.
Hood
MILLIVOLT
Ignitor Rod
Pilot
Nozzels
ELECTRONIC
Proper Flame
Adjustment
Pilot
Nozzle
Figure 8
6
Figure 9

Log Placement

WARNING: LOGS GET VERY HOT AND
WILL REMAIN HOT UP TO ONE HOUR
AFTER GAS SUPPLY IS TURNED OFF.
HANDLE ONLY WHEN LOGS ARE COOL.
TURN OFF ALL ELECTRICITY TO THE
³⁄₈" Min
(9 mm)
APPLIANCE BEFORE YOU INSTALL
GRATE AND LOGS.
WARNING: THIS APPLIANCE IS NOT
MEANT TO BURN WOOD. ANY AT-
Thermopile
TEMPT TO DO SO COULD CAUSE IR-
REPARABLE DAMAGE TO YOUR APPLI-
ANCE AND PROVE HAZARDOUS TO
YOUR SAFETY.
3/8 To 1/2 Inch
(9 mm to 13 mm)
WARNING: THE SIZE AND POSITION ON
THE LOG SET WAS ENGINEERED TO GIVE
YOUR APPLIANCE A SAFE, RELIABLE
AND ATTRACTIVE FLAME PATTERN. ANY
ATTEMPT TO USE A DIFFERENT LOG
SET IN THE FIREPLACE WILL VOID THE
Ground
Electrode
WARRANTY AND WILL RESULT IN IN-
COMPLETE COMBUSTION, SOOTING,
Flame
Sensor
AND POOR FLAME QUALITY.
Hot Surface
Igniter
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
These appliances are fitted with a pair of deco-
rative non-combustible concrete logs that are
wired in place on the log grate at the factory.
Normally these logs never have to be reposi-
tioned. Occasionally they may be removed for
cleaning, or just the front log may be removed
to provide greater access to the pilot assembly
and the control compartment below.
To remove the logs, untie the wires securing he
logs to the grate. These wires are only required
for shipping and should be completely cut
away before repositioning the logs on the grate.
Refer to Figure 9 for log placement. Align the
rear log with the slots on its bottom engaging
the grate tines. Position the front log, centered
on the grate and with the rear log behind it.
Decorative volcanic stone is available to en-
hance the look of the fireplace presentation.
Decorative volcanic stone should be spread
evenly through non-uniformly over the entire
bottom surface of the firebox to provide the
look of an ember bed.