RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes. This appliance is
only for use with the type of gas indicated on
the rating plate. This appliance is not convert-
ible for use with other gases, unless a certi-
fied kit is used.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WH Report No. J20006722
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTALLATION
INSTRUCTIONS
STANDARD SERIES
36" B-VENTED GAS APPLIANCES
P/N 700,003M REV. H 05/2004
MODELS
Millivolt Models
B-40RMN
B-40RMP
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
Electronic Models
B-40REN
B-40REP
1

Advertisement

Table of Contents
loading

Summary of Contents for Superior B-40RMN

  • Page 1 INSTALLATION INSTRUCTIONS RETAIN THESE INSTRUCTIONS STANDARD SERIES FOR FUTURE REFERENCE 36" B-VENTED GAS APPLIANCES P/N 700,003M REV. H 05/2004 MODELS This appliance may be installed in an after- market permanently located, manufactured Millivolt Models Electronic Models home (USA only) or mobile home, where not B-40RMN B-40REN prohibited by local codes.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS The electronic appliances are designed to op- WARNING: THESE FIREPLACES ARE erate on either natural or propane gas. An VENTED DECORATIVE GAS APPLIANCES. electronic direct intermittent pilot system pro- Introduction ........page DO NOT BURN WOOD OR OTHER MATE- vides safe, efficient operation.
  • Page 3: Location

    Millivolt appliances may be fitted at time of Carbon Monoxide Poisoning: Early signs of These appliances are equipped with an inte- manufacture with either a Honeywell millivolt carbon monoxide poisoning are similar to the gral combustion air door and actuator arm. gas control valve or as SIT millivolt gas control flu with headaches, dizziness and/or nausea.
  • Page 4: Appliance Specifications

    Venting APPLIANCE SPECIFICATIONS Gas Vent Rule – Gas vent caps are not permit- 4" " ted within 8 feet (2.4 mm) of a vertical wall or (102 mm) (146 mm) similar obstruction. Gas vent caps that are located 8' or more from a portion of a building "...
  • Page 5: Framing Specifications

    FRAMING SPECIFICATIONS PRE-INSTALLATION NOTES Back Wall of Chase/Enclosure Including Finishing Materials if any The fireplace may be installed directly on a combustible floor or raised on a platform of an appropriate height. Do not place fireplace on carpeting, vinyl or other soft floor coverings. It may, however, be placed on flat wood, ply- wood, particle board or other hard surfaces.
  • Page 6 Step 2. Route gas line (Figure 8) using tech- IMPORTANT: UNDER NO CIRCUMSTANCES CAN 4” Type B niques and materials prescribed by local and/ THE FIREPLACE TOP SPACERS ( FIGURE 2 ) BE Vent or national codes. It is recommended that a REMOVED OR MODIFIED, NOR MAY YOU NOTCH gas line of "...
  • Page 7: Field Wiring

    Step 5. Field Wiring – Refer to Section A for Note: Optional wall switch not supplied. If the Step 6. Connecting Gas Line – Make gas line optional wall switch is not installed, the ends of millivolt appliances and Section B for electronic connections.
  • Page 8 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however D. When the gas lines are tested and leak free, the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where observe the individual tongues of flame on the the white supply wire is connected.
  • Page 9: Appliance Operation

    To operate, push the end of the actuator to the Subsequent lightings of the appliance will not left as shown in Figure 18 , until it "pops" free require such purging. Inspect the pilot flame of its "locked" position. Pull the actuator (remove logs, if necessary, handling care- forward to open the combustion air door, and fully).
  • Page 10: Millivolt Appliance Checkout

    Millivolt Appliance Checkout No smoke or soot should be present. If sooting 3/8 To 1/2 Inch (9 mm to 13 mm) conditions exist, the air shutter opening on the The pilot flame should be steady, not lifting or main burner can be adjusted. Normally, the floating.
  • Page 11: Finishing Requirements

    FINISHING REQUIREMENTS INSTALLATION ACCESSORIES 0" (0 mm) Clearance to Combustible Wall Details and Combustible Mantels Side Wall The following accessory items are available for Max. Projection 12" (305 mm) Complete finished interior wall. To install the use in the installation of this appliance. appliance facing flush with the finished wall, position framework to accommodate the thick- Outside Air Kits Models FOAK-4 and FOAK-4LD...
  • Page 12: Gas Conversion Kits

    Gas Conversion Kits AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION WARNING: THIS CONVERSION KIT SHALL BE IN- SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE STALLED BY A QUALIFIED SERVICE AGENCY IN CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET ACCORDANCE WITH THE MANUFACTURER'S IN- TOUTES EXIGENCES ET CODES APPLICABLES DE STRUCTIONS AND ALL APPLICABLE CODES AND L'AUTORISÉS AVOIR LA JURIDICTION.
  • Page 13: Electronic Appliances

    Electronic Appliances See Figure 30 and replace the pilot orifice as follows: Remove the ignitor assembly retainer Step 8. Honeywell Electronic Valves - See clip, and carefully remove the ignitor assembly. Figure 31 and the instructions provided with Exercise extreme care to prevent damage to the kit.
  • Page 14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 16 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 700,003M REV.

This manual is also suitable for:

B-40renB-40rmpB-40rep

Table of Contents