Chapter 12: Tester Internal Batteries

The Tester uses 6 AA, 1.5-volt batteries (alkaline recommended)
to allow testing of batteries down to 1 volt and supply power
while the menu is active. The analyzer can test batteries down
to 5.5 volts when the internal batteries are not functioning.

Battery Power Indicator

The square in the upper left corner of the display indicates
the charge level of the battery pack. The square is black when
the battery pack is fully charged. It gradually changes to white
as the charge level declines. The Tester will display a warning
message when the batteries need replacing.
Full
Decreasing
Power Level Indicator for AA Batteries

Replacing the Tester Batteries

1.
Turn the Tester face down.
2.
Use a Philips screwdriver to remove the screw securing
the door to the battery compartment.
3.
Lift the door at the tab and place it aside.
4.
Remove the discharged batteries.
5.
Insert new batteries as shown, make sure the positive and
negative terminals are positioned correctly.
6.
Reposition the door on the battery compartment.
7.
Reinsert and tighten the screw.
Midtronics B.V.
Hoofdveste 6–8
Chapter 12: Tester Internal Batteries
Low
Powered
by vessel
battery
Houten NL

Troubleshooting

If you have problems with the display or printer try these
troubleshooting suggestions:

Problems with the display

The display does not turn on:
Check the connection to the battery.
The analyzer's internal batteries may need to be replaced.
The display flickers or is dim:
The contrast may need to be adjusted in the Utility menu.
The analyzer's internal batteries may need to be replaced.

Data Will Not Print

The internal printer will not print
The analyzer must be connected to the vessel battery to
print to the internal printer.
The vessel battery may be too low to power the printer.
(Battery with at least 11.5 volts)
Verify that the paper is properly installed
Verify that the paper sensor is clean and undamaged