Cleaning of PM controller
Remove PM controller.
Loosen the two Allen screws and disconnect PM
controller in two parts.
Rinse the two parts and mount again.
Carefully loosen the brass jacket. ALWAYS use 10 mm
Allen key. NEVER use pipe wrench.
Remove spring. Unfold diaphragm. Rinse diaphragm and
piston. Check the sliding of the piston and connected
spindle.
Mount diaphragm, spring and brass jacket.
Clean DCW strainer.
Mount PM controller with new sealings.
Setting of PM controller
The PM controller can operate in three basic settings:
High
Standard (default)
Low
Approx
mate setting of PM controller is dependent on district
i
heating supply temperature and t
District
Heating flow
0,2 - 0,5
60 - 70°C
Low
70 - 80°C
Low
80 - 90°C
Low
Above90°C
Standard
Brass
jacket
Spring
Diaphragm
Cut
FILL IN THIS SLIP AND RETURN THIS TOGETHER WITH THE PM CONTROLLER
NOTE: (ONLY FOR CONTROLLERS, WHICH ARE MAXIMUM 18 MONTHS).
Delivery address:
Stamp / Telephone:
Contact person:
Customer's address:
Differential pressure t (bar)
0,5 - 1,0
Low
Standard
Standard
Standard
High
High
Piston
DCW (Strainer)
Setting changes
Dismount lever by using the enclosed Allen wrench.
Remove plastic cap with red/blue markings.
Mount lever again and turn it 360:
counter-clockwise - Low
clockwise - High
Mount plastic cap and lever again.
DHW tap temperature
The tap temperature is set (within the setting area) by turning
the handle towards red: hotter, towards blue: colder.
Temperature should be set during hot-water tapping (tap load
8-10 liter per minute) at 45-48°C.
Control temperature during tapping.
Recommended tap temperature 45-48°C, never higher than
50C (to avoid lime scale precipitation in plate heat
exchanger for DHW).
Cost-free repairs
Danfoss agrees to repair or replace at the discretion of
Danfoss such Products that on Danfoss' examination are
found to be defective at the time of delivery due to faulty
manufacture, design and/or defective materials, provided
Customer makes a claim to Danfoss within 12 months from
the date of delivery, however not exceeding 18 months from
the date stamped on the product. If defects occur within the
above mentioned period, the Product shall be forwarded to
> 1,0
Danfoss together with a written notice describing the reason
for returning the Product. Freight and insurance shall be paid
by Customer. Products returned shall be free of extraneous
High
equipment. If Danfoss' examination shows that the Product is
High
not faulty, the Product shall be returned to Customer. Freight
and insurance shall be paid by Customer. If Danfoss
ascertains that the Product is faulty, Danfoss shall send the
repaired or a replacement Product to Customer.