7. Connect wires, color to color, on terminal blocks TB1 and TB3
(Figure D). TIGHTEN SECURELY! All wires must be hooked up
securely or damage could result.
8. Install control box door and reinstall the cabinet side panels.
9. The electrical supply for this product must include a suitably rated
isolating switch and circuit breaker to comply with local electrical
regulations. This RCD/GFCI circuit breaker must be installed at the
power supply in the house electrical box.
Figure A (Equipment Area for Maxxus/Aspen Models)
2
9
Note: Equipment location (such as pumps, CLEARRAY®
system, drain, heater etc.) varies by model.
1.
Control Box
2.
Power Supply Entrance(s)
3.
Jets Pump
4.
Jets Pump
5.
Jets Pump
6.
Blower
7.
Heater
8. Hot Tub Drain (Removable
External Drain Cap)
SPA CONTROLLER
12
11
3
4
14
880 EXPORT SERIES
13
7
1
5
10
9. Pump Drain Plug(s)
10. Filter/Circulation Pump
11. CLEARRAY® (Ultraviolet) Water
Purification System
12. Electronic Ballast (for the
CLEARRAY System)
13. Control Panel
14. Quick Drain
6
2
8
9