Step 5
Mount the switch onto the wall.

7 Cabling the Switch

NOTE
The cables connected to the switch must be routed along the inner side of the pole.
The ground cable must be purchased separately.
7.1 Connecting the Ground Cable to the Switch
Step 1
Connect one end of the ground cable to the switch.
Pole ground bar
7.2 Connecting Cables to the Maintenance Compartment
Cable Outlet Diameter Requirements
1
2
M6
3 N·m
No.
Cable Type
3
4
Optical fiber/
1
Optical cable
2
Ethernet cable
DC or AC output
3
power cable
AC input power
4
cable
M6 (1 PCS)
3 N·m
Step 2
Connect the other end of the ground
cable to the pole ground bar.
Supported Cable Outer Diameter
8±0.5 mm to 9.6±0.5 mm (on the left outlet) and
13.3±0.5 mm (on the right outlet)
Cat5e and Cat6 Ethernet cables
9.3±0.5 mm
9.5±0.5 mm (on the left outlet) and 14±0.5 mm
(on the right outlet)
7
M6
3 N·m