ANALOG CONTROLLER

In units equipped with analog controllers, the
frypot thermostat has been replaced with a
solid-state temperature probe and solid-state
electronics mounted on the control panel, re-
ducing the number of moving parts and elimi-
nating the need to calibrate the thermostat.
The temperature probe is connected to the
control circuitry via an interface board behind
the control panel.
The cooking temperature setpoint is set by ro-
tating the Temperature Knob to the desired
temperature.
When the Power switch is placed in the ON
position, electrical current is supplied to the
CF SERIES GAS FRYERS
CHAPTER 3: OPERATING INSTRUCTIONS
Power
Heat
On
Mode
Light
Light
Frymaster
Power
Temperature
Switch
ANALOG CONTROLLER
Melt
Trouble
Cycle
Light
Light
?
SOLID STATE
C
F
Melt Cycle
Knob
Switch
fryer's components and the Power On Light
illuminates.
Placing the Melt Cycle switch in the ON
position causes the burner to cycle on for a
few seconds and off for a longer period until
the temperature in the frypot reaches 180ºF
(82ºC). At that time the unit automatically
enters the heat mode, causing the burner to
remain lit until the setpoint is reached. When
in the melt cycle, the Melt Cycle Light
alternately illuminate and go out as the burner
cycles on and off. When the unit enters the
heat mode, the Heat Mode Light
illuminate and remain on until the setpoint is
reached. The Trouble Light indicates probe
circuit or high limit circuit problems.