Circulation pump always off
Circulation pump always on
Circulation pump operating in automatic mode without sensor 3 temperature validation. In this
mode the circulation pump will be activated only by the diferential of temperature (S1-S2)
Circulation pump operating in automatic mode with sensor 3 temperature validation. In this
mode the circulation pump will be activated by the diferential of temperature (S1-S2) and
when the temperature at sensor 1 is bigger than at sensor 3.
Confirm the selection by pressing key
SET
the function.
5.7 - Disabling the temperature sensor 3
To disable the solar backing`s temperature sensor (sensor 3) enter the functions menu and access
function
.After entering the function press the
display, press the
SET
key to confirm and exit.
When the sensor 3 is disabled the solar backings 1 and 2 will be controlled by sensor 2 (reservoir/pool).
If the circulation pump is adjusted for operation with sensor 3 validation and the sensor 3 was
deactivated the controller will automatically disable the validation.
6. SIGNALING
Sensor 1 (collectors) disconnected or out of range
Sensor 2 (reservoir /pool) disconnected or out of range
Sensor 3 (solar backings) disconnected or out of range
Temperature for sensor 1 is freezing
Temperature for sensor 1 is overheated
Temperature for sensor 2 is overheated
Configuration parameters not programmed or out of range
Circulation pump in off manual mode
Circulation pump in on manual mode
7. UNIT SELECTION (°C / °F)
To define the unit that the system will use to operate, enter into the functions menu
access code "231" and confirm it by hitting key
to choose between:
or
and confirm with key
message will appear, and the instrument will return to the function
the parameters should be reconfigured, since they assume "standard" values.
8. WIRING DIAGRAM
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
230V
115V
0
A
B
Power
supply
To the terminal
of
the distribution box
Above the current specified
MICROSOL II plus
9 - 8
115V
9 - 7
230V
Note: The sensor cable length can be increased by the user until 200 meters using PP 2 x 24 AWG
cable.
Integrating Controllers, RS-485 Serial Interface and Computer
®
A
A
B
B
RS-485 Network
A B
A
A
A
A
A
B
B
B
B
B
A B
A B
Instrument
B
A
B
A
B
Distribution Box
Used to connect more than one instrument to the Interface. The wire's connections must
be made in agreement with the following rules: terminal of the instrument connects to
A
the terminal of the distribution box, that must be connected with the terminal of the
A
Interface. Repeat the action for terminals and
B
, being
The terminal
of distribution box must be connected to the respective terminals
each instrument.
. The message
will be displayed, showing the end of
button until the message
SET
. The indication
will appear, press
SET
.After selecting the unit the
. Whenever the unit is altered,
10
11
12
10
11
12
Pump
Load 1
Load 2
Tear dimensions
to position the instrument
in the panel
Loads
supply
72 mm
use contactor
Serial interface
RS-485 Network
RS-485
Full Gauge
A
B
A B
A
B
A B
External
A B
mesh
A
terminal
grounded
MOD 64
A
RS-485 Serial Interface
the cable shield.
Device used to establish the
of
connection Full Gauge Controls'
®
instruments with the Sitrad
IMPORTANT
According to the chapters of norm IEC 60364:
1:
Install
protector against overvoltage
2:
Sensor cables and signal cables of the computer may be joined, but not in the same electric conduit
through which the electric input and the activation of the loads run.
3:
Install transient suppresors (RC filters) parallel to the loads as to increase the product life of the
relays.
For more information, please contact our Technical Support by e-mail:
phone +55 51 3475.3308.
Schematic for the connection of supresors
appears in the
to contactors
A1
using the
or
A
B
.
on the power supply.
Schematic for the connection of supresors to
direct activation loads
A1 and A2 are the
contactor coil terminals.
A2
PROTECTIVE VINYL:
This adhesive vinyl (included inside the packing) protects the instruments against
water drippings, as in commercial refrigerators, for example.
Do the application after finishing the electrical connections.
Remove the protective paper
and apply the vinyl on the entire
superior part of the device,
folding the flaps as indicated by
the arrows.
support@fullgauge.com
or by
For direct activation the maximum
Load
specified current should be taken
into consideration.
Need help?
Do you have a question about the MICROSOL II plus and is the answer not in the manual?