1. DESCRIPTION
Differential temperature controller for automation of solar heating systems,
becomes simple the management of the temperature of the water in the thermal reservoirs and
swimming pools, use the solar energy better..
It acts in the command of the water circulation pump through the differential of temperature between the
solar collectors and the thermal reservoir or swimming pool. It is a dedicated instrument that has all its
parameters of configuration protected by access code.
It makes use of two solar backing outputs, that can be electric, gas, diesel or also to program the filtering
of the swimming pool. solar backing 1 is tied with an schedule that allows the configuration of up to four
daily events for each day of the week and solar backing 2 can optionally be configured for functioning in
set with the schedule.
It has functions that prevent the water freezing and overheating in the tubings and a clock with internal
battery to guarantee its synchronism, even in the energy lack, per many years. The instrument has serial
communication for connection with the SITRAD via Internet.
Product complies with CE (European Union) and UL Inc. (United States and Canada).
*
The UL approval is only valid for Microsol II plus models with 115/230Vac power supply.
2. APPLICATION
• Solar heating pumped systems
3. TECHNICAL SPECIFICATIONS
- Power supply:
Microsol II plus: 115 or 230Vac ± 10% (50/60Hz)
Microsol II L plus: 12 or 24Vac/dc
- Control temperature:
Sensor 1: -50 to 200°C / -58 to 392°F
Sensors 2 and 3: -50 to 105°C / -58 to 221°F
- Resolution:
0.1°C between -10 and 100°C and 1°C in the rest of the range
1°F in all range
- Dimensions:
71 x 28 x 71mm
- Operating temperature:
0 to 50°C / 32 to 122°F
- Operating humidity:
10 to 90% RH (without condensation)
- Sensors:
S1 - Sensor of the collectors
S2 - Sensor of the Reservoir/Pool
S3 -Sensor for control of solar backings
- Control outputs:
PUMP - Water pump or solenoid - 5(3)A/ 250Vac 1/8HP
AUX1 - solar backing 1 - 5(3)A/ 250Vac 1/8HP
AUX2 - solar backing 2 - 5(3)A/ 250Vac 1/8HP
CLASSIFICATION ACCORDING TO IEC60730-2-9 STANDARD:
- Temperature limit of the installation surface:
- Type of construction:
Built-in electronic controller
- Automatic action:
Type 1
- Control of pollution:
Level 2
- Impulse voltage:
1,5kV
- Temperature for the test of sphere pressure:
- Insulation:
Class II
4. ADVANCED SETTINGS
4.1 - To access the options menu
Press
and
simultaneously for two seconds until it appears
appears
press
(tap) and enter the code (123) through keys
SET
press the key
SET
. Through the keys
and
manner to adjust them. To leave the menu and return to normal operations, press
appears.
4.2 - Options
Access code entry
Advanced configuration functions
Events planner operating mode
Scheduling in the events planner
Adjustment of the clock and the day of the week
MICROSOL II plus
DIFFERENTIAL TEMPERATURE
CONTROLLER FOR SOLAR HEATING
WITH TWO SOLAR BACKING
Ver.03
MICROSOL II plus
®
*
50°C
75°C and 125°C
, then releasing it. When
and
. To confirm,
access the other functions and proceed in the same
(long hit) until
SET
4.2.1 - Settings parameters
Fun
Description
Indication of the preferential temperature
Differential for turning on the water circulation pump
Differential for turning off the water circulation pump
Minimum temperature at S1 to switch on the pump
Pump switch on delay
Negative differential (S1-S2) to switch on the pump to
dissipate heat
Minimum temperature at S2 to allow activating heat
dissipation
Antifreeze S1 to switch on the pump
Antifreeze hysteresis
Minimum antifreeze time
Overheating temperature S1 to switch off the pump
Overheating hysteresis to switch on the pump
Overheating temperature S2 to switch off the pump
Overheating hysteresis to switch on the pump (S2)
Solar backing 1 operating mode
Solar backing 1 temperature setpoint
Solar backing 1 activation hysteresis
Minimum value for solar backing 1 temperature setpoint
Maximum value for solar backing 1 temperature setpoint
Solar backing 1 manual activation time
Solar backing 2 operating mode
Solar backing 2 temperature setpoint
Solar backing 2 activation hysteresis
Minimum value for solar backing 2 temperature setpoint
Maximum value for solar backing 2 temperature setpoint
Solar backing 2 manual activation time
Cyclic timer on time
Cyclic timer off time
Event schedule linking mode
Minimum S1 temperature alarm
Maximum S1 temperature alarm
S1 temperature indication offset
S2 temperature indication offset
S3 temperature indication offset
RS-485 network address
4.2.1.1 - Parameters description
Indication of the preferential temperature
It allows the preferential temperature indication to be configured. You may choose between:
temperature in the sensor 1
temperature in the sensor 2
temperature in the sensor 3
differential temperature (S1-S2)
Differential for turning on the water circulation pump
It allows the adjustment of the differential temperature (S1-S2) to activate the water circulation pump. As
the solar collectors receive energy, the temperature in sensor S1 increases. When this temperature is at a
value established as being above the temperature of sensor S2, the pump is turned on and circulates
under the heated water, storing it in the reservoir, for example.
Differential for turning off the water circulation pump
It allows the adjustment of the differential temperature (S1-S2) to turn off the water circulation pump. With
the pump on, the hot water circulates below and cools upwards. After which time, the temperature
difference between S1 and S2 tends to decrease. When this difference falls to an established level, the
pump is turned off and the water circulation stops.
Minimum temperature at S1 to switch on the pump
Minimum temperature at sensor 1 to allow switching on the water circulation pump. To deactivate It, just
decrement the value until the message OFF is displayed.
Pump switch on delay
It allows setting the minimum time the pump must be switched off before being switched on again. It
prevents switching the pump on and off at short intervals, thus increasing pump's service life. It also
defines the delay to switch on the pump after switching on the controller.
Negative differential (S1-S2) to switch on the pump to dissipate heat
Negative differential (S1-S2) to switch on the water circulation pump. Its allows dissipating heat to
reduce any excess temperature in the water tank. To deactivate It, just increment the value until the
message
is displayed.
Minimum temperature at S2 to allow activating heat dissipation
Minimum temperature at sensor 2 to allow activating the heat dissipation functions.
E251415
CELSIUS
FAHRENHEIT
Min Max Unit
Standard
Min Max Unit
Standard
0
3
-
1
0
3
-
1
1.0
40.0
°C
8.0
2
72
°F
14
1.0
40.0
°C
4.0
2
72
°F
7
-50.0
200
°C
-50.0
-58
392
°F
-58
0
999
sec .
0
0
99
sec.
0
-40.0
0.0
°C
0.0
-72
0
°F
0
0.0
105
°C
105
32
221
°F
221
-18
10.0
°C
3.0
-1
50
°F
37
0.1
20.0
°C
1.0
1
36
°F
1
0
999
sec.
0
0
999
sec.
0
0.0
200
°C
90.0
32
392
°F
194
0.1
20.0
°C
1
1
36
°F
1
0.0
105
°C
105
32
221
°F
221
0.1
20.0
°C
1.0
1
36
°F
1
0
1
-
0
0
1
-
0
-50.0
105
°C
35.0
-58
221
°F
95
0.1
20.0
°C
1.0
1
36
°F
1
-50.0
105
°C
-50.0
-58
221
°F
-58
-50.0
105
°C
105
-58
221
°F
221
999
min.
0
0
999
min.
0
0
0
5
-
0
0
5
-
0
105
°C
30.0
-58
221
°F
86
-50.0
0.1
20
°C
1.0
1
36
°F
1
105
°C
-50.0
-58
221
°F
-58
-50.0
-50.0
105
°C
105
-58
221
°F
221
999
min.
0
0
999
min.
0
0
1
999
min.
1
1
999
min.
1
999
min.
1
1
999
min.
1
1
0
3
-
0
0
3
-
0
200
°C
-50.0
-58
392
°F
-50.0
-58
-50.0
200
°C
200
-58
392
°F
392
5.0
°C
0.0
-9
9
°F
-5.0
0
-5.0
5.0
°C
0.0
-9
9
°F
0
5.1
°C
0.0
-9
10
°F
-5.0
0
1
247
-
1
1
247
-
1

Advertisement

loading

Summary of Contents for Full Gauge Controls MICROSOL II plus

  • Page 1 Overheating temperature S1 to switch off the pump °C 90.0 °F The UL approval is only valid for Microsol II plus models with 115/230Vac power supply. Overheating hysteresis to switch on the pump 20.0 °C °F Overheating temperature S2 to switch off the pump °C...
  • Page 2 Antifreeze S1 to switch on the pump Event schedule linking mode It allows setting the temperature for which the collectors start to ice. When the temperature at the It allows linking the solar backing outputs to one or more of the four daily events. The possible modes are: collectors (sensor 1) is too low (e.g.
  • Page 3 5.2 - Functions Shortcut to adjust the parameter F13 This shortcut is used when the Microsol II plus is installed to control swimming polls heating systems. In this case the parameter F13 adjusts the maximum confort temperature of the pool water.