Description Of The Connections - Nice Wil Instructions And Warnings For The Fitter

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

3.3) Description of the connections

Here is a brief description of the possible connections of the unit to the outside:
3
1-2
: 230 V a.c.
3-4
: Flashing light
5-6
: 24 V d.c.
7
: Common
8
: Courtesy Light
9
: C.A. Indicator
10
: Stop
11
: Photocell
12
: Photocell2
13
: Step-by-Step
14
: Open-Timer
15
: Close
41-42
: 2nd radio channel = Output for the second radio receiver channel if existing
43-44
: Aerail
The remaining connections are done in the factory but for the sake of completeness here is the list:
TRANS.PRIM.
TRANS.SECOND.
MOTOR
There are an additional two slots for optional cards:
RADIO
CHARGE
= 230 V a.c. 50/60 Hz
= Output for connection to the 24 V d.c. flashing light, maximum lamp power: 25 W
= 24 V d.c. output for supplying accessories (Photocell, Radio, etc.) maximum 200 mA
= Common for all inputs (terminal 6 can also be used as the Common)
= 24 V d.c. output for the courtesy light, maximum output power 10 W
= Input with STOP function (Emergency, shutdown or extreme safety)
= Input for safety devices (Photocells, pneumatic edges)
= Input for safety devices with triggering in the opening phase (Photocells, pneumatic edges)
= Input for safety devices with triggering
= Input for cyclic functioning (OPEN STOP CLOSE STOP)
= Input for opening (which can be timer controlled)
= Input for closing
= Input for the radio receiver aerial
= Primary of the power transformer
= Secondary of the power transformer
= Output for 24 V d.c. motor connection
= Slot for Nice radio receivers
= Slot for battery charge card