Quinsyn Xp - Quincy QSI-90 Instruction Manual

Direct drive air compressors
Table of Contents

Advertisement

Section VI - Compressor Fluids

QuinSyn XP

QuinSyn XP is the factory fi ll for high
pressure units (defi ned as units over 150
psig full fl ow).
QuinSyn XP is a custom blended
polyolester (POE) fl uid ideally suited for
rotary screw air compressors. QuinSyn XP
is an ISO 68 viscosity fl uid with a 12,000
hour life at 100 & 125 psig full fl ow under
normal operating conditions and 8,000
hours as a high pressure fl uid (exact fl uid
life is determined by the fl uid sampling
program).
Typical Properties of QuinSyn XP
Viscosity @ 100°F ASTM D445
Viscosity @ 210°F ASTM D445
Viscosity Index ASTM D2270
Specifi c Gravity 60/60
Flash Point ASTM D92
Fire Point ASTM D92
Applications
QuinSyn XP is designed for applications
where the fl uid is exposed to elevated
temperatures for extended periods of time.
50
Fluid thermostat temperature settings
can be elevated to assist in reducing
water content in the fl uid in high humidity
applications. Consult Quincy's Service
Department before making thermostat
changes.
Disposal
QuinSyn XP is considered nonhazardous
waste. Disposal of this fl uid should be
done in accordance with Local, State, and
Federal regulations. Should condensate
need to be treated, Quincy's QIOWA fl uid/
water separators are required.
ISO 68
60.0 cSt.
9.8 cSt.
Fluid Analysis Program
131
QuinSyn XP will be analyzed similar to
QuinSyn although the primary concern is
0.95
the total acid number (TAN).
570°F
645°F
To m a i n t a i n e x t e n d e d w a r r a n t y
compliance, fluid samples of QuinSyn
XP must be sent to Quincy Compressor
Fluid Analysis a minimum of every
2,000 hours or every 6 month for light
use units.
NOTICE!
®

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qsi-140Qsi-120Qgv-30Qgv-20Qgv-25

Table of Contents