Download Print this page

Safety Notes; Installation Instructions; Symbol Description - Hans Grohe MySport M 1jet Instructions For Use And Assembly Instructions

Advertisement

Available languages

Available languages

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 5)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 7)
Flow diagram (see page 7)
Spare parts (see page 8)
Fault
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded
base
Hot water temperature too low
2
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 4)
English
Cleaning (see page 6)
Operation (see page 6)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
65°C
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Exchange O-ring
- Set hot water limiter

Advertisement

loading

This manual is also suitable for:

Ecos m 1jetFocus m41 160 1jet