Error Table; Table "A" - Parameters - BFT ALENA SW2 CPEM Installation Manual

Hide thumbs Also See for ALENA SW2 CPEM:
Table of Contents

Advertisement

ERROR TABLE:

Unlit
Reverse due to
obstacle - Amperostop
Lit
- Try turning the board off and back on or
press button S2. If the problem persists, con-
tact the technical assistance department.
Internal system supervision control error.
- Try switching the board off and back on
slow
again.
flashing
- If the problem persists, contact the technical
assistance department.
- Thermal overload protection triggered on
one of the 2 motors

TABLE "A" - PARAMETERS

Any modification of parameters/logics must be confirmed by pressing S2 > 5s
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
Slowdown
T3
time [s]
Motor 1 closing
T4
delay time [s]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces must be limited with the use of EN12978 compliant active safety edges
INSTALLATION MANUAL
Lit
Photocell test,
Costa o Costa 8k2 failed
- Check photocell connection and/or logic
settings
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.
wARNING: It affects impact force directly: make sure that current safety requirements are met with
1
100
the set value (*).
To comply with the current safety regulations, install anti-crushing safety devices (**).
Note: if this parameter is modified, a new Autoset must be carried out.
Sets the slowdown time performed at the end of each opening and closing operation.
0
30
0 = Slowdown disabled
NOTE: Do not use with hydraulic motors.
Motor 1 closing delay time with respect to motor 2.
0
25
NOTE: set 0 for single motor operations (leaf 1).
Led ERR
slow flashing
Thermal cutout
- Allow automated device to cool
Changed settings and/or Operating logics
press S2 for 5s to confirm.
Description
fast flashing
25
ALENA SW2 CPEM -

Advertisement

Table of Contents
loading

Table of Contents