Fault Repair; Foot Switch Does Not Operate The Roller; Service; Foot Switch (2S26, 2S27) Removal - Miele B 890 Technical Information

Hide thumbs Also See for B 890:
Table of Contents

Advertisement

Technical Information
3

Fault Repair

3.1

Foot Switch Does Not Operate the Roller

Cause:
Switch defective.
Remedy:
Replace the foot switch; see Section 010-4.1.
4

Service

4.1

Foot Switch (2S26, 2S27) Removal

1. Tilt the ironing table to its horizontal position; see Section 020-4.1.
2. Lay the iron on its back, on a mat or blanket to prevent scratching.
3. Remove the two T20 screws next to the two access holes underneath the
foot plate.
4. Remove the pedal.
5. Remove the T20 screw securing the switch holder.
6. Disconnect the wiring harness from the appropriate switch and remove
the switch.
Note:
When re-inserting the bottom screws, slide the plastic holder/spring
assemblies into the correct positions so that the guide pins engage in their
holes.
4.2

Main Electronic (N2) Replacement

1. Tilt the ironing table to its horizontal position; see Section 020-4.1.
2. Lay the iron on its back, on a mat or blanket to prevent scratching.
3. Tie a sturdy cord (such as twine) to the J-hook at the bottom of the spring.
4. Release tension from the Bowden cable by disconnecting the tension
spring. Grab the J-hook at the bottom of the spring with pliers and pull it
off of the base to disengage the spring.
Warning!
With the spring disconnected, movement of the ironing table will be
unrestricted because there is no tension holding it in place.
5. Bring the iron to its upright, stowed position (see the operating manual).
6. Remove the main electronic's cover (T20 screw) from the stand (Figure
010-3, Item 1).