Mira Select Installation And User Manual page 17

Thermostatic mixer
Hide thumbs Also See for Select:
Table of Contents

Advertisement

2.5 Fit the supply pipework (Hot - Left,
Cold - Right).
Note! If the connections are reversed,
complete the installation then refer to
section: "Reversed Inlet Supplies"
before commissioning.
2.6 Loosen the Grubscrew with the
2.5 mm Hexagon Key (supplied)
and remove the Backplate from the
Mixer.
2.7 Secure the Backplate to the wall
using the Screws (supplied).
Caution! It is essential at this point
that the supply pipework is thoroughly
fl ushed through before connection to
the unit. Failure to do so may result
in product malfunction.
2.8 Fit the Compression Nuts and Olives
onto the pipework.
2.9 Align the unit with the pipework
and fit onto the Backplate. Minor
misalignment of the pipework can be
accommodated by the inlets, which
are adjustable between 149 and
154 mm centres.
2.10 Tighten the Compression Nuts onto
the Mixer with a suitable Spanner.
Caution! Take care not to damage
the chrome surfaces.
2.11 Tighten the Grubscrew to secure the
unit to the Backplate.
2.12 Fit the Shower Fittings. Refer to the
"Shower Fittings Installation and
User Guide" for further details.
Note! For high pressure systems, a
12 litre/minute white Flow Regulator
(supplied) can be fi tted under the
Hose Washer (refer to illustration).
2.13 Turn on the hot and cold water
supplies and check for leaks.
2.14 Before using the Shower, refer
to section: "Commissioning"
for testing the unit is operating
correctly.
Flow Regulator
(for high pressure
systems)
17
Grubscrew

Advertisement

Table of Contents
loading