Installation; General - Hatco GLO-RAY GRHW Series Installation And Operating Manual

Mini-merchandisers
Table of Contents

Advertisement

General

Glo-Ray
GRHW Series mini-merchandisers are shipped with
®
most components pre-assembled. Care should be taken when
unpacking shipping carton to avoid damage to unit and
components enclosed.
WARNING
ELECTRIC SHOCK HAzARD: unit is not weatherproof.
Locate unit indoors where the ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAzARD: Locate unit a minimum of 1" (25 mm) from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
The National Sanitation Foundation (NSF) requires that
units over 36" (914 mm) in width or weighing more than
80 lbs. (36 kg) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point of
use, 4" (102 mm) legs are included to allow for proper
cleaning access below unit.
NOTICE
Do not drag or slide unit when moving or installing.
Carefully lift unit to prevent the rubber feet from tearing off.
1. Remove the unit from the box.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPORTaNT OWNER INFORmaTION section for
details.
2. Remove tape and protective packaging from all surfaces of
unit.
3. Install the sneeze guard. Refer to the "Installing the Sneeze
Guard" procedure in this section.
4. Install the side panels, if equipped. Refer to the "Installing
the Side Panels" procedure in this section.
5. Tighten thumbscrews holding the front and rear personnel
protectors in place until snug, if equipped.
Thumbscrew
Figure 8. Personnel Protector Installation
(GRHW-1SG model shown)
Form No. GRHWm-0111
CAUTION
Personnel
Protector
6. Place the unit in the desired location. Two people are
required for this step.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
avoid areas that may be subject to active air movements
or currents (i.e., near exhaust fans/hoods and air
conditioning ducts).
• make sure the unit is at the proper counter height in an
area convenient for use.
• make sure the countertop is level and strong enough to
support the weight of the unit and food product.
Installing the Sneeze Guard
all models are shipped with sneeze guards. Use the appropriate
procedure to install a sneeze guard on a unit.
NOTE: Make sure to install the sneeze guard before installing
side panels, if equipped.
GRHW-1P, -2P, -1SG, and -1SGS Models
1. assemble each weld screw through the top of the sneeze
guard and through the support trim. Loosely thread a cap
nut onto each of the weld screws below the support trim.
2. Lift the sneeze guard assembly and carefully slide each of
the weld screws that are loosely attached to the sneeze
guard into the channel on the unit.
3. align each end of the sneeze guard with the ends of the unit
and then tighten the cap nuts to secure the sneeze guard in
position. Do not over-tighten the cap nuts.
Weld
Screw
Cap Nut
Figure 9. Installing a Sneeze Guard
(GRHW-1SG model shown)
7

INSTALLATION

Channel
Channel
Sneeze
Guard
Support
Trim
continued...

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents