Summary of Contents for Frico PAECS

  • Page 1 Original instructions PAECS ..25 ... 9 ..12 ..14 ..17 ..21 ..33 ..40 ..29 ..37 ..44...
  • Page 2 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene Les pages de présentation contiennent principalement des images.
  • Page 3 PAECS 1012/1522/2012 1050/1560/2050 1; 1,5 m 1,8 m 90,5 min 500 1,5 m 1,8 m min 500 min 500 1,5 m Fig. 1...
  • Page 4 PAECS Potentiometer, Potentiometer, high speed, 6V low speed, 2.5V Fig. 2: Stepless airflow control. Internal potentiometer for low and high speed (accessible through the outlet grille). TX20 Fig.3: Open the unit.
  • Page 5 PAECS Mounting with wall brackets ø8 (3x) ø5 ø10 PAECS10 2 pcs PAECS15 2 pcs Fig. 4: Mounting with wall brackets PAECS20 3 pcs...
  • Page 6 PAECS Accessories PA34TR15 PAECS10, PAECS15, 1 m PA34TR20 PAECS20, 1 m PA2P15 PAECS10, PAECS15, 1 m PA2P20 PAECS20, 1 m PAECS10, PAECS15 PA2PF15 PA2PF20 PAECS20 PA34TR PA2P PA2PF SIReDC AGB304 SIReDC AGB304...
  • Page 7 PAECS PAECS Stepless airflow control with door contact / position limit switch SIReDC WirePAECS20 No Nc Diode PAECS10 Wire P AECS15 White Only 2 m version White/ Tach White White Red / +10 V Yellow / 0-10 V PWM Blue / GND...
  • Page 8 PAECS Ambient, no heat - PAECS Type Output Airflow Sound Sound Voltage Amperage Length Weight power* pressure* motor motor* [kW] [dB(A)] [dB(A)] [mm] [kg] PAECS10 1450* 44/62 230V~ 0,14/0,79 1050 PAECS15 2200* 45/62 230V~ 0,20/1,17 1560 3100* 51/67 230V~ 0,50/2,12...
  • Page 9 45 °. Application 4. Lock the nuts against the brackets. (Fig.4D) PAECS is an air curtain for cold storage and freezer rooms as well as entrances. Horizontal mounting on the ceiling Installation height is up to 4 metres (cold Threaded rods, hanging brackets and ceiling storage) and up to 2,5 metres (entrances).
  • Page 10 PAECS outwards to withstand the load. Generally 6. Install the new motor and/or the new speaking, the higher the load, the greater the impeller as above in reverse order. angle that is needed. Basic setting fan speed Trouble shooting The fan speed for open respectively closed...
  • Page 11 Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.se...