Original instructions
PA2500
ES
.... 34
PL
.... 59
FR
.... 39
RU
.... 64

Advertisement

loading

Summary of Contents for Frico PA2500

  • Page 1 Original instructions PA2500 ..29 ..39 ..34 ..20 ..25 ..49 ..59 ..44 ..54 ..64...
  • Page 2 PA2500 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Page 3 PA2500 PA2500 1026 / 1536 / 2026 1050 / 1560 / 2050 1026 / 1536 / 2026 90,5 min 500 1026 / 1536 / 2026 1050 / 1560 / 2050 Cu ø15 90,5 min 500 1050 / 1560 / 2050...
  • Page 4 PA2500 Gland ø17,5 Gland ø17,5 Knock-out ø32,5 ø25,5 Knock-out ø20,5 Gland Knock-out ø17,5 Fig.2...
  • Page 5 PA2500 TX20 Fig.3: Open the unit. Fig.4: Minimum distance.
  • Page 6 PA2500 Mounting with wall brackets ø8 (3x) ø5 ø10 2 pcs PA2510 PA2515 2 pcs Fig. 6: Mounting with wall brackets PA2520 3 pcs...
  • Page 7 PA2500 Accessories PA34TR15 PA2510, PA2515, 1 m PA2520, 1 m PA34TR20 PA2510, PA2515, 1 m PA2P15 PA2520, 1 m PA2P20 PA2PF15 PA2510, PA2515 PA2PF20 PA2520 PAMLK PA2500 PA2EF10 PA2510W PA2EF15 PA2515W PA2EF20 PA2520W PAWAK PA2500W PA34TR PA2P FHDN15 PA2500W PA2PF...
  • Page 8 PA2500 Accessories SIRe SIReB SIReAC SIReAA SIReB SIReUR SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 10 m SIReAC/SIReAA SIReCJ4/SIReCJ6 15 m SIReCC615 SIReCC640 40 m SIReCC403 SIReCC405 SIReCC410 10 m SIReCC415 SIReRTX SIReCC VLSP...
  • Page 9 PA2500 PA2510E05 / PA2515E08 / PA2520E10 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 10 PA2500 PA2510E08 / PA2515E12 / PA2520E16 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 11 PA2500 PA2510A / PA2515A / PA2520A PA2510W / PA2515W / PA2520W SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 12 PA2500 PA2510E05YD / PA2515E08YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 13 PA2500 PA2520E10YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 14 PA2500 PAMLK, motor alarm board SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo N F1 F2 F3...
  • Page 15 PA2500 SIReB Basic PA2500 A PA2500 E SIReUB1 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC...
  • Page 16 PA2500 SIReB Basic PA2500 W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m)
  • Page 17 PA2500 Output charts water PA2500 Supply water temperature:110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow drop air temp.
  • Page 18 PA2500 Output charts water PA2500 Supply water temperature: 60 °C Water temperature: 60/40 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +32 °C Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow...
  • Page 19: Technical Specifications

    PA2500 Technical specifications Voltage motor: 230V~ Ambient, no heat - PA2500 A Type Output Airflow* Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] PA2510A 900/1300 43/53 230V~ 1050 PA2515A 1250/2100 44/54 230V~ 1560...
  • Page 20 Om väggen är ojämn måste konsolerna kompenseras för detta. Användningsområde 2. Haka på aggregat i nederkant på konsolerna. PA2500 är avsedd för installationshöjd upp till (Fig.6B) 2,5 meters höjd. Luftridån finns utan värme, med elvärme och med vattenburen värme.
  • Page 21 (Fig.3) Observera att aggregatet ska föregås av en 3. Efter service, reparation och skötsel ska reglerande ventil, se Frico ventilkit. frontluckan sättas tillbaka. Fäst luckan i Anslutning av vattenbatteri sker på nederkant med den bockade kanten och aggregatets ovansida via släta kopparrör...
  • Page 22 PA2500 Skötsel Temperaturreglering Temperaturreglering i SIRe avser att begränsa Aggregat med vattenburen värme utblåstemperaturen. Om temperaturen Apparatens filter bör rengöras regelbundet för ändå skulle överskrida inställt värde avges att säkerställa ridåverkan och värmeavgivning överhettningslarm. Läs mer i manualen för från apparaten. Hur ofta beror på de lokala SIRe.
  • Page 23 PA2500 Felsökning Säkerhet Om fläktarna inte går eller inte blåser tillräckligt, • Vid alla installationer av elvärmda kontrollera följande: produkter bör jordfelsbrytare 300 mA för • Att insugsgallret/filtret inte är smutsigt. brandskydd användas. • Funktioner och inställningar i styrsystem • Säkerställ att området kring apparatens SIRe, se manual för SIRe.
  • Page 24 Output* [kW] Effekt Return water temperature [°C] Returvattentemperatur Water flow [l/s] Vattenflöde Pressure drop [kPa] Tryckfall ) Rekommenderad utgående lufttemperatur för en god komfort med optimerat effektuttag. ) Nominell effekt vid given framlednings- och returtemperatur. Se www.frico.se för ytterligare beräkningar.