Page 1
..15 ..21 Frico AB certifies that the PAEC3200CA, PAEC3200CE and PAEC3200CW air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Page 2
11.00 9.07 Frico AB certifies that the PAEC3200CA, PAEC3200CE and PAEC3200CW air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
2165 1785 Frico AB certifies that the PAEC3200CA, PAEC3200CE and PAEC3200CW air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
PAEC3200C Output charts water PAEC3200CW Metric chart Supply water temperature:80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water flow drop air temp.
Page 5
PAEC3200C The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Les pages de présentation contiennent principalement des images. Pour la traduction des textes en anglais, consultez la page correspondante à la langue souhaitée.
Page 6
PAEC3200C DN20 (3/4"), outside thread F / D / B 1045 / 1555 / 2045 1045 / 1555 / 2045 1045 / 1555 / 2045 E / C / A 1068 / 1578 / 2068 min 500 1068 / 1578 / 2068 1068 / 1578 / 2068 min 500 min 500...
Page 11
PAEC3200C PAEC3200CA/W 208V1~ L1 L2 5A x 3 Only 2 m version SENSOR 0 - 10V DOOR PE N 6 5 4 AFTER WATER Only water PE N 6 5 4 White / Tach Red / +10 V Yellow / 0-10 PAEC3200CA/W NA AREC3200CA/W NA Blue / GND...
Page 12
PAEC3200C PAEC3200CE-208V 0 -10V N H1H2 N F1 F2 F3 Yellow Blue White...
Page 13
PAEC3200C PAEC3200CE-480V/600V 0 - 10V N H1H2 N F1 F2 F3 Yellow Blue White...
Page 14
PAEC3200C • Read the safety instructions before performing installation and/or maintenance activities on the unit. • Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. • The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
PAEC3200C Installation and operating instructions General Instructions Mounting with wall brackets (fig. 6) Read these instructions carefully prior to 1. Mount the brackets on the wall, see fig.6A installation and use. Keep this manual for and dimension drawing fig.1. If the wall is future reference.
Note that the unit shall be preceded by a removed. regulating valve, see Frico valve kit. The water coil is connected on top of the unit via steel pipes with DN20 (3/4’’) terminals, Service, repairs and maintenance external thread.
PAEC3200C Replacing motor or impeller Maintenance Unit with water heating 1. Remove the front. The appliance filter should be cleaned regularly 2. Remove gable end. to ensure the air curtain effect and heat 3. Remove the screw between motor and fan. emission from the device.
Page 18
PAEC3200C For units with electrical heating, also check the Safety following: • For all installations of electrically heated • Power supply to electric heater coil; check products a residual current circuit breaker fuses and circuit-breaker (if any). 300 mA for fire protection should be used. •...
Page 19
PAEC3200C Control The air curtain has an integrated control system and can be remotely controlled. 208V~ Black Actuator SD230 (remove the quick Brown connector) Blue PA2DR External on/off Eg time switch. External potential free closure = off Factory setting dip-switches - Unit without heating Factory setting dip-switches - Unit with water or with electrical heating heating...
PAEC3200C Fan step 1/2/3 ~20 °C Heat step Electric: Half/full power Water: On/off (1 LED) On/off Control panel - Unit with electrical heating or water heating Fan step 1/2/3 On/off Control panel - Unit without heating Remote control - on/off, fan steps and heating steps Functional test Temperature control Functional test is started using the remote...
Page 23
Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net.
Need help?
Do you have a question about the PAEC3200C Series and is the answer not in the manual?
Questions and answers