Outdoor Model
Indoor Model
(*1)
Actual Cooling Capacity T1
(*2)
Actual Cooling Capacity T3
(*1)
Actual Cooling Input Power T1
(*2)
Actual Cooling Input Power T3
(*1)
Total Amps T1
(*2)
Total Amps T3
(*1)
EER T1
(*2)
EER T3
Voltage
Frequency
Refrigeration Charge
Annual Energy Consumption
Country of Origin
(*1) : Cooling capacity : Indoor 27°C DB / 19°C WB - Outdoor 35°C DB
(*2) : Cooling capacity : Indoor 29°C DB / 19°C WB - Outdoor 46°C DB
Unpacking the Unit
1. Pull the securing flap outwards until it is in line with the carton's surface.
2. Lift and remove the carton and the pad. Figure 2.
3. Remove hold-down brackets.
Btu/h
KW
Btu/h
KW
Watts
Watts
Ampere
Ampere
Btu/h/W
Btu/h/W
Volt
Hertz
Kg
In
KWh/Year
Indoor Unit
Outdoor Unit
Securing Flap
Figure 1
1.5TR
2TR
RR20AVAK9
RR25AVAK9
FDMRN20AVAK
FDMRN25AVAK
18,000
23,000
5.27
6.74
16,500
21,000
4.83
6.15
1,385
1,769
1,833
2,333
6.5
8.3
8.0
10.3
13.00
13.00
9.00
9.00
230
230
60
60
2.211
1.743
3739.5
4776.3
3
2.5TR
3TR
RR30AVAK9
RR36AVAK9
FDMRN30AVAK
FDMRN36AVAK
28,000
34,000
8.20
9.96
24,000
29,000
7.03
8.50
2,154
2,615
2,667
3,222
10.1
12.3
12.4
15.0
13.00
13.00
9.00
9.00
230
230
60
60
2.013
2.381
5815.8
7060.5
Malaysia
United States of America
Carton
Pad
Literature
Packet
Hold-Down
Brackets
3.5TR
RR42AVAK9
FDMRN42AVAK
39,000
11.43
33,000
9.67
3,120
3,667
15.1
18.3
12.50
9.00
230
60
2.807
8424.0
Figure 2