Set the battery selector switch (Fig. 1, Pos. 1) to the correct position
using a thin object (e.g. a ballpoint pen):
Lead gel battery: Set the battery selector switch to "Lead-gel".
F
Lead acid battery: Set the battery selector switch to "Lead-acid".
F
Start up the system as described in Section 3.1.
3.3

System faults

In most cases of a fault in the energy supply system, a flat battery or a faulty
fuse is the cause.
If the battery is discharged, consumers can always be supplied by starting
the motor of the base vehicle.
Please contact our customer service department if you can not rectify the
fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the electrobloc
repaired at a specialist workshop. Please note that the warranty becomes
void if incorrect repair work is carried out. Schaudt GmbH can not accept
liability for any damages resulting from such repairs.
Fault
Living area battery is not
Living area battery is not
charged during 230V
g
g
operation (battery voltage
constantly below 13 3 V)
constantly below 13.3 V)
Living area battery is
overcharged during 230V
operation (battery voltage
constantly above 14.5 V)
Starter battery is not
Starter battery is not
charged during 230V
g
g
operation (battery voltage
constantly below 13 0 V)
constantly below 13.0 V)
Living area battery is not
g
charged during mobile
h
d d i
operation (battery voltage
operation (battery voltage
below 13.0 V)
The living area battery is
overcharged during
mobile operation (battery
voltage constantly above
14.3 V)
The refrigerator does not
work during mobile
operation
p
Possible cause
No mains voltage
No mains voltage
Too many consumers are
switched on
Defective electrobloc
Defective electrobloc
No mains voltage
No mains voltage
Too many consumers are
switched on
Defective electrobloc
y
Defective alternator
bil
No voltage on D+ input
Defective electrobloc
Defective alternator
No power supply to the
refrigerator
Defective electrobloc
Defective refrigerator
Date: 20.01.2010
Remedy
Switch on the automatic
Switch on the automatic
circuit breaker in the vehicle;
check the mains voltage
Switch off any consumers
not required
Contact the customer
service department
Contact the customer
service department
Switch on the automatic
Switch on the automatic
circuit breaker in the vehicle;
check the mains voltage
Switch off any consumers
not required
Contact the customer
service department
Check the alternator
Check the fuse and wiring
Contact the customer
service department
Check the alternator
Check the fuse (20A of the
supply; possibly 2A of the
D+ signal) and wiring
Contact the customer
service department
Check the refrigerator
;
;