Schaudt LR 1218 Instruction Manual

Schaudt LR 1218 Instruction Manual

Solar charge regulator
Hide thumbs Also See for LR 1218:

Advertisement

E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de
822.212 BA / EN
Instruction Manual
LR 1218 Solar Charge Regulator
Inhaltsverzeichnis
1
Safety Information
1.1
Meaning of safety symbols
1.2
General safety information
2
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
System faults
5
Technical data
6
Application and functions in detail
7
Maintenance
Appendix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2
2
3
3
3
4
4
4
5
Date: 22.09.2009

Advertisement

Table of Contents
loading

Summary of Contents for Schaudt LR 1218

  • Page 1 ..........E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de 822.212 BA / EN...
  • Page 2 Instruction manual for solar charge regulator LR 1218 Safety Information Meaning of safety symbols DANGER! Failure to heed this warning may result in death or serious injury. WARNING! Failure to heed this warning may result in personal injuries. ATTENTION! Failure to heed this warning may result in damage to the device or connec- ted consumers.
  • Page 3 The instruction manual should be kept in the vehicle at all times. Ensure that other users are made aware of the safety regulations. The LR 1218 solar charge regulator is for charging the batteries of the mo- torhome by means of the connected solar module. The solar charge regula- tor limits and controls the charging voltage of the batteries.
  • Page 4 Instruction manual for solar charge regulator LR 1218 Fault Possible cause Remedy Batteries are not being Defective batteries Have the batteries charged checked If batteries are in perfect Contact the customer working order: service department Solar charge regulator defective Defective electronic block...
  • Page 5 Instruction manual for solar charge regulator LR 1218 Appendix EC Declaration of Conformity Schaudt GmbH hereby confirms that the design of the device complies with the following relevant regulations: Directive on electromagnetic compatibility 2004/104/EC dated 14.10.2004 2005/49/EC dated 25.07.2005 2005/83/EC dated 23.11.2005...
  • Page 6 Instruction manual for solar charge regulator LR 1218 Fault report In the event of damage, please return the defective device together with the completed fault report to the manufacturer. Device type: _______________________ Article no.: _______________________ Vehicle: Manufacturer: _______________________ Model: _______________________...
  • Page 7: Table Of Contents

    ..... . E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de 822.212 BA / EN...
  • Page 8: Safety Information

    Installation instructions for solar charge regulator LR 1218 Safety Information Meaning of safety symbols DANGER! Failure to heed this warning may result in death or serious injury. WARNING! Failure to heed this warning may result in personal injuries. ATTENTION! Failure to heed this warning may result in damage to the device or connec- ted consumers.
  • Page 9: Introduction

    Always follow the relevant instruction manual in addition to the installation instructions. Scope of delivery Delivered as part of the LR 1218 solar charge regulator: 1 x LR 1218 solar charge regulator Connection set for the different applications Instruction Manual Installation instructions Fig.
  • Page 10: Mechanical Installation

    On a stable and even surface, attach the solar charge regulator to the " drillholes with three screws (Fig. 1, Pos. 6). Fig. 1 Dimension Diagram of LR 1218 Solar Charge Regulator (dimensions in mm) Date: 22.09.2009 822.212 MA / EN...
  • Page 11: Electrical Connection

    Installation instructions for solar charge regulator LR 1218 Electrical connection ATTENTION! The output voltage of the charge regulator is not suitable for direct supply without battery. Malfunction of or damage to connected consumers: Do not operate the solar charge regulator without a battery.
  • Page 12 Installation instructions for solar charge regulator LR 1218 LR 1218 Fig. 2 Circuit diagram of connection LR 1218 to starter battery and living area battery Pos. Name Fuse for starter battery charge current (20A) Fuse for living area battery charge current (20A)
  • Page 13: Connection To An Electrobloc Ebl

    DT ... / LT ...) LR 1218 black brown white brown Fig. 3 Circuit diagram of connection LR 1218 to EBL ... with DT ... / LT ... Pos. Name Cable with electrobloc connector: -- X1 brown negative battery -- X2 red...
  • Page 14: Connection To An Electrobloc Ebl

    EBL ... connector cable (caravan battery charge current) EBL ... adapter cable (starter battery charge current) LR 1218 black brown yellow brown black blue Fig. 4 Circuit diagram of connection LR 1218 to EBL ... Date: 22.09.2009 822.212 MA / EN...
  • Page 15: Block Diagram/Connection Diagram

    Installation instructions for solar charge regulator LR 1218 Pos. Name Cable with electrobloc connector: -- X1 blue negative battery -- X2 not assigned -- X3 black + living area battery Electrobloc adapter cable -- Ya to available electrobloc cable -- Yb to electrobloc...
  • Page 16: Initial Use

    Installation instructions for solar charge regulator LR 1218 Initial use Checks prior to initial use Before starting up Ensure that all the connections are correct (only for initial use). " Ensure that the batteries or the electrobloc are connected (depending on "...
  • Page 17: Electrical Data

    Installation instructions for solar charge regulator LR 1218 Electrical data Nominal voltage 12 V Regulating principle pulse-width modulated series regulator charge curve (with solar module) IU Final charge voltage 14.2 V living area battery (has priority) 14.2 V starter battery Solar charge regulator approx.
  • Page 18 Installation instructions for solar charge regulator LR 1218 (blank page) Date: 22.09.2009 822.212 MA / EN...

Table of Contents