Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Safety Information Meaning of safety symbols DANGER! Failure to heed this warning may result in death or serious injury. WARNING! Failure to heed this warning may result in personal injuries. ATTENTION! Failure to heed this warning may result in damage to the device or connec- ted consumers.
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Introduction This device is intended solely for use in vehicles. This instruction manual contains important information for safe operation of the device. Ensure you read and follow the safety instructions provided. The instruction manual should be kept in the vehicle at all times.
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Outputs are exceptions: Floor light/step AES/compressor refrigerator Heater Spare 4 Frost protection valve These outputs are not disabled via the main switch of the IT ... /LT control and display panel.
If this is not possible, e.g. if you are abroad, you can have the electrobloc repaired at a specialist workshop. Please note that the warranty becomes void if incorrect repair work is carried out. Schaudt GmbH can not accept liability for any damages resulting from such repairs.
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Fault Possible cause Remedy Solar charging does not Solar charging does not Solar charge regulator Solar charge regulator Plug in solar charge Plug in solar charge work not plugged in regulator Defective fuse or wiring...
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Application and functions in detail The electrobloc is the central power supply unit for all 12V consumers in the vehicle’s electrical system. It is usually located in a cupboard or storage area and is accessible from the front in order to change fuses.
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Battery functions Suitable batteries 6-cell lead acid or lead gel batteries, 55 Ah and above Battery charging Simultaneous charging of the starter battery and the living area battery via during mobile operation the alternator, parallel connection of the batteries via a cut-off relay Battery isolation...
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Additional functions Automatic switch This relay supplies the AES/compressor refrigerator with power from the function for starter battery when the vehicle engine is running and the D+ connection is AES/compressor live.
Schaudt battery charger LAS ... with max. 18 A charge current, including suitable connection cable (MNL). Solar charge regulator Schaudt Solar charge regulator type LR ... for solar modules with a total cur- rent of 14A with 3-pole connection plug and connection cable Customer service Customer service Schaudt GmbH, Elektrotechnik &...
Page 11
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Fault report In the event of damage, please return the defective device together with the completed fault report to the manufacturer. Device type: _______________________ Item no.: _______________________ Vehicle: Manufacturer: _______________________ Model:...
Page 13
Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP Block diagram/connection diagram LASO 1218--6 Selector switch lead gel/ S 1218--5 lead acid MNL socket cap 2F block 7 Mains 230V~50Hz + Auxiliary charger Low power device socket Negative charger Minus, living area battery must be connected externally to Minus, starter battery.