Download Print this page
WilTec 61541 Operation Manual

WilTec 61541 Operation Manual

Garden pump

Advertisement

Quick Links

Operation Manual
Garden Pump - 61540, 61541
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ
insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities please contact us.
© by WilTec Wildanger Technik GmbH
Seite 11
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

Advertisement

loading

Summary of Contents for WilTec 61541

  • Page 1 Operation Manual Garden Pump - 61540, 61541 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments, illustrations, functioning steps and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us.
  • Page 2 The information contained in this document is subject to change without prior notice. No part of this document can be copied or duplicated in another form without the prior written consent of WilTec Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in this user manual or the connection diagram.
  • Page 3: Introduction And Safety

    14) Please ensure that the power supply can satisfy the connection regulations before the equipment connection. 15) Please don't bend, extrude, pull or drive the power wire to avoid the related dangers caused by line breakage. © by WilTec Wildanger Technik GmbH Seite 13 http://www.WilTec.de http://www.aoyue.eu...
  • Page 4 Please ensure that the suction pipeline has enough water supplies. The terminal of suction  hose shall be submerged in water at all the time. All components of pressure pipeline shall be compressive and must only be installed by pro-  fessionals. © by WilTec Wildanger Technik GmbH Seite 14 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 5: Operation

    4) In case of outdoor operation, the electrical connection shall be splash-proof. This equipment shall not be operated in water. 5) The extension wire shall have enough conductor cross section. The cable drum must be unfolded completely. © by WilTec Wildanger Technik GmbH Seite 15 http://www.WilTec.de http://www.aoyue.eu...
  • Page 6: Maintenance

    5) The filling pressure will reach up to the parameters data. 6) Connect the devices again, check its function and increase the precharge pressure. 7) Clean the filter after use. Filling and suction concerning MODEL 61541 1) Unscrew the pump cover. 2) The pump shall be filled with water completely.
  • Page 7 Then immerse the water inlet in water least. for more than 10 cm. 7. The joint of suction pipeline Please replace the joint sealing element and is untightened. completely seal the joint. © by WilTec Wildanger Technik GmbH Seite 17 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 8: Technical Data

    IPX4 Max. head Max. suction height Max. conveying amount 3600 l/h 4200 l/h 4500 l/h Work pressure 1.5 ~ 3.0 bar 1.5 ~ 3.0 bar 1.5 ~ 3.0 bar © by WilTec Wildanger Technik GmbH Seite 18 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de...
  • Page 9 FAULT AND REMEDIAL MEASURES (61541) Model 61541 Error Reasons Response measures 1. Power voltage is absent? Please check the power cable, plug, socket and fuse. 2. The overheating engine is Find out the specific reasons and solve it. mainly caused by: excessively high liquid temperature.
  • Page 10 All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.