ARTICLE Fuel Oil Pump and Diesel Pump
Item number 50588,50589, 50591, 50592, 50747, 50748, 50767, 50958, 51486,
51564, 62132, 62133, 62137
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignific -
antly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Advertisement

loading

Summary of Contents for WilTec 50588

  • Page 1 Operation Manual ARTICLE Fuel Oil Pump and Diesel Pump Item number 50588,50589, 50591, 50592, 50747, 50748, 50767, 50958, 51486, 51564, 62132, 62133, 62137 Illustration similar, may vary depending on model Read and follow the operating instructions and safety information before using for the first time.
  • Page 2 © by WilTec Wildanger Technik GmbH Seite 2 http://www.WilTec.de http://www.aoyue.eu November 2020 Version 11 http://www.teichtip.de...
  • Page 3 The information contained in this document is subject to change without prior notice. No part of this document can be copied or duplicated in another form without the prior written consent of WilTec Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in this user manual or the connection diagram.
  • Page 4 (sand). It must NOT pump water or easy flammable liquids (petrol). Field of application  For conveying and transferring fuel oil (heating oil) or diesel fuel. © by WilTec Wildanger Technik GmbH Seite 4 http://www.WilTec.de http://www.aoyue.eu November 2020 Version 11...
  • Page 5 750 W Voltage/Frequency 230V/50Hz Max. flow rate 100 l/min Max. delivery height 25 m Suction head maximum Temperature range -30 bis +40°C Connection 1“ IG © by WilTec Wildanger Technik GmbH Seite 5 http://www.WilTec.de http://www.aoyue.eu November 2020 Version 11 http://www.teichtip.de...
  • Page 6 0,5 min - 5 min. By longer suction times the medium to be pumped should be refilled.  If the pump is removed after being used, it has to be newly refilled before it is connected and op- erated again. © by WilTec Wildanger Technik GmbH Seite 6 http://www.WilTec.de http://www.aoyue.eu November 2020 Version 11 http://www.teichtip.de...
  • Page 7 Before every maintenance work the pump must be switched off, pull out the plug from the power socket. After long non-operation periods check if a proper turning of the rotor takes place.  © by WilTec Wildanger Technik GmbH Seite 7 http://www.WilTec.de http://www.aoyue.eu November 2020 Version 11 http://www.teichtip.de...
  • Page 8 Engine overloaded – excessive friction Dismantle the pump and clean it, through foreign particles prevent suction of foreign particles (Filter) Attention! The pump must not run dry. © by WilTec Wildanger Technik GmbH Seite 8 http://www.WilTec.de http://www.aoyue.eu November 2020 Version 11 http://www.teichtip.de...
  • Page 9: Disposal Regulations

    All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.