Maximum Throughput
Diversity
Host Interface
Maximum EIRP
5.7
Operating Environment
The RUGGEDCOM RX1400 is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
Ambient Storage Tem-
perature
Ambient Relative Hu-
midity
Maximum Altitude
Maximum Altitude
a
Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with
Underwriter Laboratories (UL) listed devices.
d
Non-condensing
5.8
Mechanical Specifications
Weight
Ingress Protection
Enclosure
5.9
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
RUGGEDCOM RX1400
Installation Manual, 09/2019, C79000-G8976-1103-13
-40 to 85 °C (-40 to 185 °F)
a b
-40 to 85°C (-40 to 185 °F)
5% to 95%
d
2000 m (6562 ft)
2000 m (6562 ft)
2.5 kg (5.5 lb)
IP30
Aluminum
IEEE 802.11n
TCP: 80 Mbps at 2.4 GHz
UDP: 100 Mbps at 2.4 GHz
2.4 GHz MRC support for extended range
5.0 GHz diversity capable
4-Bit SDIO
< 200 mW at 5250 to 5350 MHz
c
Technical Specifications
5.7 Operating Environment