Installation
See Page 2
Right
Hand Door - RH
Left
Hand Reverse - LHR
Top Jamb
Installation
See Page 5
Left Hand Door - LH
Right Hand Reverse - RHR
Parallel Arm
Installation
See Pages
Left Hand Door - LH
Right Hand Reverse - RHR
4
Closer
Size
Stamp
Pinion Cap

Installation Instructions

80-9323-0012-010 (01-09)
Hold Open Arm Models
An Incorrectly installed or improperly adjusted
door closer can cause property damage or
personal injury. These installation instructions
should be followed to avoid the possibility of
misapplication or misadjustment.
NOTE: For special applications a separate
door and frame preparation template is
packed with these instructions. Use this
instruction sheet for installation sequence
and closer adjustments only.
Doors should be hung on ball bearing or
anti-friction hinges.
A separate door stop is recommended.
Door and frame must be properly
reinforced.
Adjust closing time speed between 3 and 7
seconds from 90° to 0°.
3 & 4
These door closers should NOT be
installed on the exposed side (weather
side) of exterior doors.
#7
Metal
Standard Components
Closer Body
"L"Valve
"S"Valve
Sized
Weaker
(Sizes 2,3,4,5)
-
2312BC
2313BC
2314BC
Stronger
2315BC
+
3/16"
1/4-20
Wood
Set
Screw
Assembly
Non Handed Door Closer
Regular Arm
Top Jamb
Parallel Arm
Regular Arm
Installation
See Page 2
Left
Hand Door - LH
Right
Hand Reverse - RHR
Top Jamb
Installation
See Page 5
Right Hand Door - RH
Left Hand Reverse - LHR
Parallel Arm
Installation
See Pages
3 & 4
Right Hand Door - RH
Left Hand Reverse - LHR
Self Drilling Screws
Wood and Metal
For Wood drill 3/16 hole
Drill 9/32 thru from Closer Side
Thru Bolt and Grommet Nut
Machine Screws
Drill 9/32 thru from Closer Side
#7 Drill, 1/4-20 Tap
Optional Components
Main Arm
Soffit Adapter Plate
Arm
(Optional)
Sleeve Nut and Bolt
3/8 Drill other side
3/8 Drill other Side
2588 Soffit Plate
Used with Parallel
Arm Closers Only

Advertisement

loading

Summary of Contents for Yale 2310BC Series

  • Page 1: Installation Instructions

    Installation Instructions Non Handed Door Closer 80-9323-0012-010 (01-09) Regular Arm Top Jamb Hold Open Arm Models Parallel Arm Sized 2310BC Weaker (Sizes 2,3,4,5) Series 2312BC 2313BC Regular Arm Regular Arm 2314BC Installation Stronger Installation 2315BC See Page 2 See Page 2 An Incorrectly installed or improperly adjusted door closer can cause property damage or personal injury.
  • Page 2 2310BC Series Hold Open Door Closers — Regular Arm 80-9323-0012-010 (01-09) Parts 1-3/4 (152) (44) 1-1/4 (32) (22) (19) 9-1/16 (230) Right Hand Shown Dimension "A" Opening To 100° (178) Inches (mm) 101° to 120° (152) Left 3-1/2 Hand 121° to 180°...
  • Page 3 2310BC Series Hold Open Door Closers — Parallel Arm 80-9323-0012-010 (01-09) Parts 2-3/4 Right Hand Shown (70) (10) (50) 7/16 (13) (11) Inches (mm) (178) 4 1-1/2 (102) (38) Optional Top of Door Door Opening 2-1/8 9-1/4 8-5/8 7-5/8 Frame To 100°...
  • Page 4 2310BC Series Hold Open Door Closers — Parallel Arm 80-9323-0012-010 (01-09) Open Valves Assemble Arm Right Hand Door Flat Left Hand Caution: Door Do Not Back Valves Out Completely Flat Sweep Latch Arm Screw Faster Slower Faster Slower 1-1/2 Arm Screw...
  • Page 5 2310BC Series Hold Open Door Closers — Top Jamb Arm 80-9323-0012-010 (01-09) 9-1/16 Parts (230) (19) Top of Door 1-1/2 (38) (13) 1-3/4 (44) (152) Right Hand Shown Inches Door/Wall/Hardware/Jamb (mm) conditions permitting Dimension "A" Opening 9 0 ° 7-1/2 To 100°...
  • Page 6 Yale ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Tel: (800)-438-1951 • Fax: (800)-338-0965 Copyright © 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. www.yalecommercial.com Sweep...

This manual is also suitable for:

2312bc2315bc2313bc2314bc