Source language: German Safety instructions Content For your protection • Read the operating instructions in full before starting up and fol- Page low the safety instructions. Device setup/Display Accessories • Keep the operating instructions in a place where they can be accessed by Declaration of conformity Interface and output everyone.
Page 3
• Firmly secure the accessories and vessels in place, otherwise shaking vessels Unpack could be damaged or projected out. • Check the appliance and accessories beforehand for damage each time you Unpack use them. Do not use damaged components. - Please unpack the device carefully •...
Page 4
Commissioning Operating modes Mode A Mode B (with speed limiter) (without speed limiter) Touch mode max. 3000 1/min max. 3000 1/min (with standard attachment 3000 3000 MS 3.1) with/without timer Continuous mode max. 1300 1/min max. 3000 1/min (with all attachments) 3000 1300 with/without timer...
Page 5
Setting Timer / min: sec Change Timer Time SET TIME Mode Timer min:sec Setting SET 1/min 1300 Set the desired time min: sec SET TIME SET 1/min Confirm Time 1300 Countdown runs min: sec An audible signal will be given Start SET TIME Stop...
Accessories Possible uses and permitted speed ranges of attachments: Designation Description Ident- Nr. Touch mode Continuous mode Speed range (rpm) Mode MS 3.1 For test tubes and small vessels upto 3426300 0/100-3000 A and B 0/100-1300 Standard attachment ø 50 mm 0/100-3000 MS 3.3 For different rubber foam inserts...
Changing attachments Interface and output The device is equipped with a 9-pin SUB-D connector on the rear side of the device. Serial interface RS 232 C MS 3.1 The serial assignment of the socket can be used to control the device exter- nally by means of a PC and a suitable application program, e.g.
The communication of the laboratory device and the PC requires the following MSR individual units. Rev. 1.1) adapter and cables, available by IKA. Overview of the NAMUR-Instructions PC 2.1 Cable Abbreviations: This cable is required to connect the 9-pin connector to a PC.
+5 - +40 For this, use the “certificate of compliance” form which you can obtain Perm. relative humidity from IKA or can download a version for printing from the IKA website at Protection type acc. to DIN EN 60529 IP 21 www.ika.com.
Subject to technical changes! Warranty In accordance with IKA warranty conditions, the warranty period is 24 months. For claims under the warranty please contact your local dealer. You may also send the machine direct to our works, enclosing the delivery invoice and giving reasons for the claim.